                                                600.105UK User Manual

 

 

To avoid possible electric shock or personal injury, and to 
avoid possible damage to the Meter or to the equipment 

under test, please adhere to the following rules: 

 

 

Before using the Meter inspect the case. Do not 

use the Meter if it is damaged or the case (or part 

of the case) is removed. Look for cracks or missing 
plastic. Pay attention to the insulation around the 

connectors. 

 

Inspect the test leads for damaged insulation or 

exposed metal. Check the test leads for continuity. 

 

Do not apply more than the rated voltage, as 

marked on the meter, between the terminals or 
between any terminal and grounding. 

 

The rotary switch should be placed in the right 
position and no changeover of range should be 

made during measurements being conducted to 
prevent damage of the Meter. 

 

When the meter is working at an effective voltage 

over 60V in DC or 30Vrms in AC, special care 
should be taken due to danger of electric shock. 

 

Use the proper terminals, function, and range for 

your measurements. 

 

Do not use or store the meter in an environment of 

high temperature, humidity, explosive, 
inflammable, and strong magnetic fields. The 

performance of the meter may deteriorate after 
being exposed to moisture. 

 

When using the test leads always keep your 

fingers behind the finger guards. 

Summary of Contents for 600.105UK

Page 1: ...Please read this manual thoroughly and ensure all contents are fully understood before use of the apparatus WARNING MTN01 Network Digital Multimeter Item Ref 600 105UK EN61010 1 2010...

Page 2: ...ltage as marked on the meter between the terminals or between any terminal and grounding The rotary switch should be placed in the right position and no changeover of range should be made during measu...

Page 3: ...e meter and accidents A soft cloth and mild detergent should be used to clean the surface of the meter on a regular basis No abrasives or solvents should be used to prevent the surface of the meter fr...

Page 4: ...LCD 3 digits 1999 count 0 5 high Polarity Automatic indicated minus assumed plus Measure method double integral A D switch implement Sampling speed 2 times per second Over load indication 1 is display...

Page 5: ...www avsl com 600 105UK User Manual Overview COM jack V mA jack 10A jack hFE socket LCD RANGE switch Cable test remote unit...

Page 6: ...for 1 year 23 5 less than 80 RH DC VOLTAGE OVERLOAD PROTECTION 220V rms AC for 200mV range and 500V DC or 500Vrms for all ranges AC VOLTAGE RESPONSE Average responding calibrated in rms of a sine wav...

Page 7: ...sounds if resistance is less then 30 20 OVERLOAD PROTECTION 15 seconds maximum 220Vrms DC CURRENT OVERLOAD PROTECTION 500mA 250V fuse 10A range infused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE R...

Page 8: ...rn on power of the device or circuit being measured and the voltage value will appear on the Digital Display along with the voltage polarity DC CURRENT MEASUREMENT 1 Red lead to V mA Black lead to COM...

Page 9: ...est lead to the anode of the diode to be measured and black test lead to cathode 4 The forward voltage drop in mV will be displayed If the diode is reversed the figure 1 will be shown TRANSISTOR hFE M...

Page 10: ...6 7 8 G RJ45 Remote unit 1 2 3 4 5 6 7 8 G Main unit 1 2 3 4 5 6 RJ11 Remote unit 1 2 3 4 5 6 FAULT DESCRIPTIONS 1 If one cable is open circuit eg no 3 then the no 3 LED on both units wont illuminate...

Page 11: ...remove the 2 screws in the bottom of the case simply remove the old and replace with a new one Be careful to observe polarity ACCESSORIES Operator s instruction manual Set of test leads red and black...

Reviews: