Cause engine overheating if trimmed up/out to a point where any cooling water intake holes are above the waterline
mc78529
Trimming sterndrive unit down/in can:
•
Help the boat accelerate and plane off quicker
•
Generally improve the ride in choppy water
•
In most cases, reduce boat speed
•
If in excess, lower the bow of some boats to a point at which they begin to plow with their bow in the water while on plane.
This can result in an unexpected turn in either direction called bow steering or over steering if any turn is attempted or if a
significant wave is encountered.
mc79530
Single Engine Trim/Trailer
Single engine applications will have a button that can be pressed to trim the sterndrive unit up or down.
To raise the sterndrive unit for trailering, beaching, launching, low speed (below 1200 RPM), and shallow water operation push
the trim button to raise the sterndrive unit to the full up/out position.
Some controls also have a trailer button that trims the sterndrive to a position suitable for trailer purposes only.
Dual Engine Trim/Trailer
NOTICE
If using external tie bars, raising or lowering the drives independently of each other can damage the drive and steering
systems. If using an external tie bar, raise and lower all drives together as a unit.
Dual engine applications may have a single integral button to operate both sterndrive units simultaneously or may have
separate buttons for each sterndrive unit.
Some controls also have a trailer button that trims the sterndrives to a position suitable for trailer purposes only.
Electrical System Overload Protection—Carbureted Engines
If an electrical overload occurs, a fuse will blow or the circuit breaker will open. The cause must be found and corrected before
replacing the fuse or resetting the circuit breaker.
NOTE: In an emergency, when the engine must be operated and the cause for the high current draw cannot be located and
corrected, turn off or disconnect all accessories connected to the engine and instrumentation wiring. Reset the circuit breaker. If
the breaker remains open, the electrical overload has not been eliminated. Further checks must be made on the electrical
system. Contact your authorized dealer as soon as possible.
Summary of Contents for 4.3 TKS series
Page 2: ......
Page 8: ...Page iv 90 8M0113857 eng DECEMBER 2015...
Page 32: ...Section 2 On the Water Notes Page 24 90 8M0113857 eng DECEMBER 2015...
Page 76: ...Section 4 Maintenance Notes Page 68 90 8M0113857 eng DECEMBER 2015...
Page 92: ...Section 5 Storage Notes Page 84 90 8M0113857 eng DECEMBER 2015...
Page 108: ......