200/225 OPTIMAX DTS
Page 22 / 42
90-10234050
Copper Battery Cable Wire Gauge Size
Wire Gauge Size Number SAE
Models
6-25 hp
30-115 hp (except OptiMax)
125-250 hp (except OptiMax)
OptiMax/Verado
Cable Length
2.4 m (8 ft.)
8
1.
6
1.
-
-
2.7 m (9 ft.)
6
4
-
-
3.0 m (10 ft.)
6
4
6
1.
-
3.4 m (11 ft.)
6
4
4
-
3.7 m (12 ft.)
6
4
4
4
1.
4.0 m (13 ft.)
6
2
4
2
4.3 m (14 ft.)
4
2
4
2
4.6 m (15 ft.)
4
2
4
2
4.9 m (16 ft.)
4
2
2
2
5.2 m (17 ft.)
4
2
2
2
5.5 m (18 ft.)
4
2
2
2
5.8 m (19 ft.)
4
2
2
2
6.1 m (20 ft)
4
2
2
2
6.4 m (21 ft.)
2
1
2
1
6.7 m (22 ft.)
2
1
2
1
7.0 m (23 ft.)
2
1
2
1
7.3 m (24 ft.)
2
1
2
1
7.6 m (25 ft.)
2
1
2
1
7.9 m (26 ft.)
2
1/0
1
1/0
8.2 m (27 ft.)
2
1/0
1
1/0
8.5 m (28 ft.)
2
1/0
1
1/0
8.8 m (29 ft.)
2
1/0
1
1/0
9.1 m (30 ft.)
2
1/0
1
1/0
9.4 m (31 ft.)
2
1/0
1
1/0
9.8 m (32 ft.)
2
1/0
1
1/0
10.1 m (33 ft.)
2
2/0
1/0
2/0
10.4 m (34 ft.)
2
2/0
1/0
2/0
10.7 m (35 ft.)
1
2/0
1/0
2/0
11.0 m (36 ft.)
1
2/0
1/0
2/0
11.3 m (37 ft.)
1
2/0
1/0
2/0
11.6 m (38 ft.)
1
2/0
1/0
2/0
11.9 m (39 ft.)
1
2/0
1/0
2/0
12.2 m (40 ft.)
1
2/0
1/0
2/0
1.
Standard (original) cable length and wire gauge size.