Mercury Security MS-I8S Installations And Specifications Download Page 5

 

Mercury Security © 2016 

MS-I8S 

DOC 10107-0055 

REV 1.01 

 Page   5 

Mechanical: 

Dimension: 

 

4.33" (110 mm)W x 5.90" (150 mm)L x .65" (16.5 mm)H 

Weight:  

 

2.7 oz. (77.3 g) nominal (w/o terminal blocks) 

 

Environmental: 

Temperature: 

 

-55 °C to +85 °C, storage 

0 °C to +50 °C, operating 

Humidity: 

 

5% to 95% RHNC 

Warranty 

Mercury  Security  warrants  the  product  is  free  from  defects  in  material  and  workmanship  under 
normal  use  and  service  with  proper  maintenance  for  one  year  from  the  date  of  factory  shipment. 
Mercury  Security  assumes  no  responsibility  for  products  damaged  by  improper  handling  or 
installation.  This warranty is limited to the repair or replacement of the defective unit. 

There are no expressed warranties other than set forth herein.  Mercury Security does not make, nor 
intends, nor does it authorize any agent or representative to make any  other warranties, or implied 
warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness 
for a particular purpose. 

Returns  must  be  accompanied  by  a  Return  Material  Authorization  (RMA)  number  obtained  from 
customer service, and prepaid postage and insurance. 

Liability

 

The Interface should only be used to control exits from areas where an alternative method for exit is 
available.    This  product  is  not  intended  for,  nor  is  rated  for  operation  in  life-critical  control 
applications.  Mercury  Security  is not liable under any  circumstances for loss or damage caused by 
or  partially  caused  by  the  misapplication  or  malfunction  of  the  product.    Mercury  Security's  liability 
does not extend beyond the purchase price of the product. 

Summary of Contents for MS-I8S

Page 1: ...he MS I8S is part of Mercury Security s bridging hardware technology for replacing the Software House I8 CSI module that provides sensor monitoring when migrating to the Mercury platform Mercury s MS I8S board has eight inputs which may be configured to support unsupervised or supervised alarm input circuits In addition one dedicated input is provided for cabinet tamper switch monitoring The MS I8...

Page 2: ...r the introduction of a foreign voltage A supervised input circuit requires adding two resistors to the circuit to facilitate proper reporting The standard supervised circuit requires 1k Ohm 1 resistors and should be located as close to the sensor as possible Custom end of line EOL resistances may be configured via the host software Grounded and foreign voltage states are not UL 294 required and t...

Page 3: ...F OFF ON Address 9 OFF ON OFF ON OFF Address 10 OFF ON OFF ON ON Address 11 OFF ON ON OFF OFF Address 12 OFF ON ON OFF ON Address 13 OFF ON ON ON OFF Address 14 OFF ON ON ON ON Address 15 ON OFF OFF OFF OFF Address 16 ON OFF OFF OFF ON Address 17 ON OFF OFF ON OFF Address 18 ON OFF OFF ON ON Address 19 ON OFF ON OFF OFF Address 20 ON OFF ON OFF ON Address 21 ON OFF ON ON OFF Address 22 ON OFF ON O...

Page 4: ...unication port 1 LED Input Status 1 2 LED Input Status 2 3 LED Input Status 3 4 LED Input Status 4 5 LED Input Status 5 6 LED Input Status 6 7 LED Input Status 7 8 LED Input Status 8 C LED Cabinet Tamper Input in the inactive state OFF briefly flashes ON every 3 seconds Input in the active state ON briefly flashes OFF every 3 seconds Input in a fault state Rapid Flash 8 Specifications The processo...

Page 5: ...than set forth herein Mercury Security does not make nor intends nor does it authorize any agent or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returns must be accompanied by a Return Material Authorization RMA number obtained from customer service and prepaid po...

Reviews: