MS-I8S PROCESSOR
Installation and Specifications:
1. General:
The MS-I8S is part of Mercury Security's bridging hardware technology for replacing the Software House
I8-CSI module that provides sensor monitoring when migrating to the Mercury platform.
Mercury's MS-I8S board has eight inputs, which may be configured to support unsupervised or
supervised alarm input circuits. In addition, one dedicated input is provided for cabinet tamper switch
monitoring. The MS-I8S requires 12 Vdc for power.
2. Supplying Power to the MS-I8S:
The MS-I8S requires 12 Vdc for power.
TB9 pin 1: Ground
TB9 pin 4: +12 VDC
Locate power source as close to the unit as possible. Connect power with minimum
of 18 AWG wires.
Observe POLARITY!