MS-I8S PROCESSOR 

Installation and Specifications: 

1.  General: 

The MS-I8S is part of Mercury Security's bridging hardware technology for replacing the Software House 
I8-CSI module that provides sensor monitoring when migrating to the Mercury platform. 
Mercury's  MS-I8S  board  has  eight  inputs,  which  may  be  configured  to  support  unsupervised  or 
supervised  alarm  input  circuits.  In  addition,  one  dedicated  input  is  provided  for  cabinet  tamper  switch 
monitoring.  The MS-I8S requires 12 Vdc for power. 
 

 

 

2.  Supplying Power to the MS-I8S: 

The MS-I8S requires 12 Vdc for power. 

TB9 pin 1: Ground 

TB9 pin 4: +12 VDC 

Locate power source as close to the unit as possible.  Connect power with minimum 
of 18 AWG wires. 

 

 

Observe POLARITY!

 

 

 

TAMPE

R

GND

+12VDC

TR+

TR-

GND

+12VDC
TR+
TR-
GND

Summary of Contents for MS-I8S

Page 1: ...he MS I8S is part of Mercury Security s bridging hardware technology for replacing the Software House I8 CSI module that provides sensor monitoring when migrating to the Mercury platform Mercury s MS I8S board has eight inputs which may be configured to support unsupervised or supervised alarm input circuits In addition one dedicated input is provided for cabinet tamper switch monitoring The MS I8...

Page 2: ...r the introduction of a foreign voltage A supervised input circuit requires adding two resistors to the circuit to facilitate proper reporting The standard supervised circuit requires 1k Ohm 1 resistors and should be located as close to the sensor as possible Custom end of line EOL resistances may be configured via the host software Grounded and foreign voltage states are not UL 294 required and t...

Page 3: ...F OFF ON Address 9 OFF ON OFF ON OFF Address 10 OFF ON OFF ON ON Address 11 OFF ON ON OFF OFF Address 12 OFF ON ON OFF ON Address 13 OFF ON ON ON OFF Address 14 OFF ON ON ON ON Address 15 ON OFF OFF OFF OFF Address 16 ON OFF OFF OFF ON Address 17 ON OFF OFF ON OFF Address 18 ON OFF OFF ON ON Address 19 ON OFF ON OFF OFF Address 20 ON OFF ON OFF ON Address 21 ON OFF ON ON OFF Address 22 ON OFF ON O...

Page 4: ...unication port 1 LED Input Status 1 2 LED Input Status 2 3 LED Input Status 3 4 LED Input Status 4 5 LED Input Status 5 6 LED Input Status 6 7 LED Input Status 7 8 LED Input Status 8 C LED Cabinet Tamper Input in the inactive state OFF briefly flashes ON every 3 seconds Input in the active state ON briefly flashes OFF every 3 seconds Input in a fault state Rapid Flash 8 Specifications The processo...

Page 5: ...than set forth herein Mercury Security does not make nor intends nor does it authorize any agent or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returns must be accompanied by a Return Material Authorization RMA number obtained from customer service and prepaid po...

Reviews: