20/09/2017
GYROLED® M130 ISO BASE SB1
GT-0657-FEUX Ind B
Head-quarters
: Zone d’Activités « Les Gailletrous » - rue Louis Pasteur- 41260 LA CHAUSSEE SAINT VICTOR - France
Tel : 00 33 (0) 2 54 57 52 52
– Fax 00 33 (0) 2 54 56 80 00
SAS au capital de 102. 400 € - APE (NAF) 2790 Z – SIRET 310 999 891 00040
Page 2
30161-01
Pin n°1 : Wire n°1 : Ground power supply GYROLED M130
Pin n°2 : Wire n°2 : NIGHT function
Pin n°3 : REAR HALF FLASH function
Pin n°4 : Wire n°4 : Operating mode selection
Pin n°6 : Wire n°6 : « + » power supply GYROLED M130
Pin n°7 : Synchronized Input mode n°1
Pin n°8 : Synchronized Input mode n°2
Pin n°9 : Output synchronisation
The GYROLED® M130 is supplied with a connector kit including 4
silk-printed wires. 4 pin Molex Minifit unwired. The connector is
equipped with the 4 basic operating wires (Power supply "+" and "-"
Selection Mode, Night Gyroled®), the other pins provided separately
correspond to the connector pin numbers and are associated with
operating options (synchronization).
To select an operating mode from among the 14 available, power the
Gyroled® M130 then apply pulses to "+ Battery" to wire n°4 until you reach
the required pattern. The selected pattern remains in the memory even if
the Gyroled® M130 has been disconnected.
Note : To enable easy identification of the flash patterns, the14th mode is
only has the central LED lit up at the top of the beacon.
The NIGHT function reduces the beacon light brightness during a night
Intervention except 13
th
pattern (Flash to rotate mode).
The REAR HALF FLASH function lights up 8 of the 13 leds to the rear.
The choice of the Gyroled® M130 position on a roof vehicle must meet regulation requirements on light signalling installation.
The Gyroled® M130 should be placed vertically, so that the light beam is projected onto a horizontal plane.
It is also very important to adhere to certain rules of proximity to other equipment. Therefore, the Gyroled® M130 must be mounted
at more than 30 centimeters away from radio or telephone equipment (transceiver, cables, antennas, filters).
It is crucial to follow recommendations about electrical wire dimensions (diameter and length) in order to maintain the efficiency of
the line protection (fuse). Also we recommend the use of 1mm² section wire for the power supply.
The protective fuse must be positioned head-on closest to the battery. Its value must take into account the consumption of the
equipment installed, as well as the length of the line itself (2A at 12 volts ; 1A at 24 volts).
The Gyroled® M130 connections must be crimped using the appropriate tools.
GYROLED® M130 POSITIONING
MOUNTING INDICATIONS
The GYROLED
®
M130 installation on the vehicle roof must be done in a
specific way. The 2 small ducts on the base must be placed to the rear.
1. Rear
2. Front