background image

Bulletin IN-0118

Page 3

1
2
3
3A
4
5
6
7
8
9
27

5S
6S
8S
9S
9AS
10S
11S
12S
13S
15S
25S
26S

26E
23E
6E
24E
9E
21E
22E
11E
13E

1/8 - 15 psig
0-30” Hg. Vac.
10” Vac 12 psig
1/8 - 20 psig
1-35 psig
2-60 psig
5-100 psig
5-150 psig
5-200 psig
10-300 psig
25” Vac 50 psig

2-60 psig
5-100 psig
10-200 psig
10-300 psig
40-350 psig
25-600 psig
50-1000 psig
100-1500 psig
300-2500 psig
500-5000 psig
30” Hg. Vac. 60 psig
30” Hg. Vac. 75 psig

30” Hg. Vac 75
5-75 psig
10-100 psig
10-150 psig
10-300 psig
30-400 psig
75-800 psig
100-1000 psig
200-2500 psig

Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass

Steel
Steel 
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel

316 S.S.
316 S.S.
316 S.S.
316 S.S.
316 S.S.
316 S.S.
316 S.S.
316 S.S.
316 S.S.

2-1/2 psig
4” Hg.
2-1/2 psig
2-1/2 psig
3-1/2 psig
5 psig
7 psig
10-5/8 psig
15 psig
25 psig
7 psig

6 psig
8 psig
10 psig
20 psig
20 psig
40 psig
100 psig
150 psig
250 psig
600 psig
5 psig
10 psig

12 psig
12 psig
12 psig
13 psig
35 psig
40 psig
85 psig
125 psig
275 psig

1/2 psig
1” Hg. Vac.
1/2 psig
1/2 psig
3/4 psig
3/4 psig 
1 psig
1-1/8 psig
1-1/4 psig
2 psig
1 psig

1-1/4 psig
2 psig
2 psig
4 psig
4 psig
7 psig
10 psig
12 psig
20 psig
150 psig
1 psig
2 psig

2 psig
2 psig
2 psig
3 psig
6 psig
8 psig
15 psig
22 psig
75 psig

For Steam and Other Applications: DA-431, -DAW-433, DAH-431

For General Pressure Applications: DA-421, DAW-423, DAH-421

316 S.S. Bourdon Tubes: DA-441, DAW-443, DAH-441

Range

No.

Adj.

Working

Range

Bourdon

Tube

Material

Minimum

Pressure Spread

Between

Switch 

Operation

Fixed Differential

Each Switch

(Sensitivity)

Two-Stage Pressure Controls, Series D-400

Ranges and Differentials

Specification No. 4122.

One circuit opens on increase of

pressure; second circuit opens on further increase of pres-
sure.

Specification No. 4129.

One circuit closes on increase of

pressure; second circuit closes on further increase of pres-
sure..

Specification No. 4132.

Both circuits open at intermediate

pressure.  One circuit closes on increase of pressure above
neutral zone; second circuit closes on decrease in pressure
below neutral zone.

Specification No. 4123.

Both circuits close at intermediate

pressure. One circuit opens on increase of pressure above
neutral zone; second circuit opens on decrease in pressure
below neutral zone.

Electrical Ratings D-400

See Code C on Page 4 in Electrical Rating Chart.

Spec. No.

Pressure

-4122

-4129

-4132

-4123

Switch

Mk.

“A”
“B”
“A”
“B”
“A”
“B”
“A”
“B”

Low

Pressure

Hi-Vac.

ON
ON

OFF
OFF

ON

OFF
OFF

ON

Intermediate

Pressure

OFF

ON
ON 

OFF
OFF
OFF

ON 
ON

High

Pressure 

Lo-Vac.

OFF
OFF

ON
ON

OFF

ON
ON

OFF

Two Stage, Series D-400
Switch Operating Specifications

When ordering, select operation desired, add suffix number
to type number of control.  Example: Type DA-431-4122.

Contact Position

0-30 Hg Vac
10” Hg Vac 12
1/8-15 psig
1/8-20 psig
1-35 psig
25” Hg Vac 50
2-60 psig
5-100 psig
5-150 psig
10-200 psig
10-300 psig

2
3
1
3A
4
27
5
6
7
8
9

2” Hg.
1 psig
1 psig
1 psig
1.75 psig
3.5 psig
3 psig
3.75 psig
6 psig
8 psig
12 psig

1” Hg.
0.5 psig
0.5 psig
0.5 psig
0.75 psig
2 psig
1 psig
2 psig
3 psig
3.5 psig
6 psig

0.2” Hg.
2 oz.
2 oz.
2 oz.
4 oz.
7 oz.
6 oz.
7 oz.
8 oz.
12 oz.
16 oz.

30” Hg Vac 60
30” Hg Vac 75
2-60 psig
5-100 psig
10-200 psig
10-300 psig
40-350 psig
25-600 psig
50-1000 psig
100-1500 psig
300-2500 psig
500-5000 psig
800-8000 psig

25S
26S
5S
6S
8S
9S
9AS
10S
11S
12S
13S
15S
16S

6 psig
8 psig
4 psig
6 psig
8 psig
14 psig
14 psig
25 psig
60 psig
90 psig
150 psig
450 psig
750 psig

3 psig
4 psig
2.5 psig
3 psig
4 psig
7 psig
7 psig
15 psig
40 psig
50 psig
100 psig
200 psig
400 psig

12 oz.
12 oz.
0.5 psig
0.75 psig
0.75 psig
1 psig
1 psig
2.5 psig
10 psig
12 psig
45 psig
150 psig
200 psig

30” Hg Vac 75
5-75 psig
10-100 psig
10-150 psig
10-300 psig
30-400 psig
75-800 psig
100-1000 psig
200-2500 psig

26E
23E
6E
24E
9E
21E
22E
11E
13E

7 psig
3 psig
7 psig
6 psig
18 psig
30 psig
75 psig
100 psig
210 psig

35 psig
2 psig
3.5psig
3 psig
5 psig
15 psig
35 psig
45 psig
110 psig

14 oz.
0.4 psig
14 oz.
0.75 psig
3 psig
5 psig
12 psig
18 psig
50 psig

Brass Bourdon

Tubes

403 Stainless Steel

Bourdon Tubes

316 Stainless Steel

Bourdon Tubes

Controls with Mercury Switches

Adjustable

Differential

Double Adjustment

for setting both ‘on and ‘off” 

operating points 

Maximum Differenial - full scale.

Minimum Differential listed below.

Fixed 

Differenital

Single Adjustment

Adjustable operating point.

Differential fixed

NOT ADJUSTABLE

APPLICATION

Bourdon tube

Material

Adjustable

Operating

Range PSIG

Range

No.

DA-31

DA-531

DS-231

Series D Pressure Controls

Ranges and Differentials

DA-21

DA-521

DS-221

DA-41

DA-541

DS-241

Note:

Differentials listed

are for SP-ST operation
only.  When controls
incorporate two mercury
switches for double
throw or two pole opera-
tion, the differentials are
approximately double
those shown for stan-
dard single pole, single
throw controls.

IN-0118  10/24/06  1:35 PM  Page 3

Summary of Contents for D Series

Page 1: ... from vibration caused by reciprocating or rotating machinery Where excessive vibration occurs use a remote connection and mount by means of a mounting bracket or separable flange available on order When in doubt about exces sive vibration use a remote connection Where pulsations pres sure surges or water hammer are present protect the control with a surge tank or scrubber Mount all controls verti...

Page 2: ...tomatically on a decrease of pressure with provision for man ual reset when pressure is below set point Prefixed by DL DLW DLE DLH A single adjustment sets the low pressure operating point of the control at any value on the scale range The control will operate automati cally at the set point only on a drop in pressure The lock type feature per mits the circuit to be reset and locked in position wh...

Page 3: ...C on Page 4 in Electrical Rating Chart Spec No Pressure 4122 4129 4132 4123 Switch Mk A B A B A B A B Low Pressure Hi Vac ON ON OFF OFF ON OFF OFF ON Intermediate Pressure OFF ON ON OFF OFF OFF ON ON High Pressure Lo Vac OFF OFF ON ON OFF ON ON OFF Two Stage Series D 400 Switch Operating Specifications When ordering select operation desired add suffix number to type number of control Example Type ...

Page 4: ...ircuit 2 Circuit SP DT SP DT SP ST SP DT ST ST DP DT Code A A B A A B A A A B B B B A B A B A B B B Circuit Response to Pressure Increase Opens Closes Closes Closes Opens Opens Closes Closes Opens One Closes as Other Opens One Closes as Other Opens Close Opens Closes Open One Closes as Other Opens One Opens as Other Closes Closes One Closes as Other Opens Opens Two Close Two Open 4P ST Close 2 9 6...

Reviews: