background image

P 7

Please retain product label and instructions for future reference

             

It is ESSENTIAL that you apply wood treat-

ment immediately after the building has 

been assembled.

AFTER TREATMENT:

score around protective

 cover on glazing and

 carefuly peel

 covering back

SILICONE

SEALANT

Step 18

It is 

ESSENTIAL

 to seal around all window 

framing with silicone sealant (not included

to minimize water ingress.

*Please note:

 This image is for illustrative 

purpose and may differ from your product (

in 

regards to the number of windows

) however 

the principle is the same.

Summary of Contents for 04GREEN0606SD-V5

Page 1: ...P 1 x2 6 X 6 GREENHOUSE ASSEMBLY INSTRUCTIONS 04GREEN0606SD V5 ...

Page 2: ...e Top AI 04GREENPGT1864X426 V5 2 3 4 1 5 Roof AI 04GREENROOF1217X1050 V1 8 Door AI 04GREENDOOR550X1720 V2 9 Opening Window AI 04GREENOW560X460 V1 6 7 8 10 11 Fascia 1075mm x4 Base Frame 1864mm x2 Base Frame 1688mm x2 9 10 11 12 Roof Support Bar 1824mm 17 18 F4444 1688mm S1256 1075mm F4444 1864mm F2744 1824mm 8mm LIP X2 66DEG CUTS S1230 556mm S1230 1717mm S1256 1824mm F2744 556mm PI 07 0004 PI 07 0...

Page 3: ... 32 Strip 560mm S1221 560mm 33 Strip 1776mm x3 S1227 1776mm 34 Strip 926mm x16 S1227 926mm 35 Strip 610mm x2 S1227 610mm Window Cill 610mm x2 Window Cill 1776mm x3 Styrene 942x570x2mm x11 Styrene 985x570mm x5 Styrene 503x570mm PI 08 0021 PI 08 0020 PI 05 0151 PI 05 0157 PI 05 0158 Nail Bag 30mm Screw x 33 20mm Screw x 6 50mm Screw x 52 70mm Screw x 8 40mm Screw x 8 16mm Screws x 6 30mm Black Screw...

Page 4: ...Step 2 Assemble the window panels on the floor Place the plastic window cill onto the lip of the window panel 1b Lay the styrene on top of each open ing so that it overlaps the surronding framing equally on both sides as per the diagram Step 3 Attatch the window strips using 3x30mm screws as per the diagram Ensure the framing does not protude the width of the window frame Ensure you screw into the...

Page 5: ...Step 5 Fix the remaining Window Side No 2 at the corner using 3 x 50mm screws in the same way as the previous step 3x50mm screws Pre drill hole 50mm screw Step 6 Fix the Door Sides x2 No 1 between the window panels using 6x50mm screws in the same way as the previous step 6x50mm Screws Pre drill hole 50mm screw Step 7 Fix the Door frame No 13 between the Door sides This allows for the door sides to...

Page 6: ... 8x50mm Screws The building can now be attached to the floor framing with 6x50mm screws per side 24x50mm Screws Pre drill hole 50mm screw Step 10 Fix the shorter Door strip No 16 to the top of the door opening with 3x30mm screws 3x30mm Screws Pre drill hole 30mm screw Pre drill hole 16mm screw 5 14 14 4 3 16 Step 11 Lay the window panel down No 5 and place the styrene sheets No 27 28 in position u...

Page 7: ...using 3x30mm screws per strip Ensure you screw to the side of the styrene 24x30mm Screws 30mm screw 16mm screw Step 13 Attach the strip No 32 onto the window panel with 4x30mm screws Drop the window No 8 into the aperture and attach the window on the roof panel using 4x16 screws and 4x30mm screws per hinge No 17 8x30mm Screws 4x16mm Screws 29 30 31 29 8 29 29 32 ...

Page 8: ... each gable and meet at the top of the apex Secure each roof panel to the building using 16x50mm screws 16x50mm Screws IMPORTANT Ensure both roof sections meet at the top of the apex as shown in the illustration Pre drill hole 50mm screw Step 14 Attach the Roof Support bar No 12 to the roof panels using 5x40mm screws Screw diagonally through the support into the roof panel as shown in the diagram ...

Page 9: ...ng 14x30mm screws as shown in the diagram 14x30mm Screws Pre drill hole 30mm screw Step 17 Fix the Roof trim No 15 to the top of the building and secure with 4x30mm screws as shown 4x30mm Screws Pre drill hole 30mm screw 9 20 9 15 Step 18 Fix the corner trims No 23 in postion using 4x30mm screws 16x30mm Screws Pre drill hole 30mm screw 23 ...

Page 10: ... TREATMENT score around protective cover on glazing and carefuly peel covering back SILICONE SEALANT Step 18 It is ESSENTIAL to seal around all window framing with silicone sealant not included to minimize water ingress Please note This image is for illustrative purpose and may differ from your product in regards to the number of windows however the principle is the same ...

Page 11: ...1 2 ...

Page 12: ......