background image

P 6

Please retain product label and instructions for future reference

       

DO NOT ALLOW YOUR CHILD TO PLAY WITH ANY 

COMPONENT PARTS PRIOR  TO ASSEMBLY.

Purlins

Ensure both purlin

edges are flush 

with rafters

Rafters

Step 6

Parts needed -            x3

 

Place Roof Purlins 

(No. 12)

 in between

each gable upright as shown in

illustration below. Use 1x70mm screw 

per end. Screw through the outside of 

building, into into framing.

We recommend finishing framing 

surfaces with sand paper to remove 

any splinters.

6x70mm  Screws.  

70mm 

screw

12

12

Step 7

Parts needed -          x2 &          x2 &          x2 

 

 

Screw the Roof Eaves x2 

(No. 11)

 on to the bottom of both Large 

Roof sheets 

(No. 7)

, using 3x30mm screws 

per eave.

 

Fix the Roof Sheets 

(No. 7 

No. 8)

 

straight into the rafter using 6x30mm 

screws per Small Roof sheet and

 8x30mm screws per

Large Roof sheet.

34x30mm  Screws.  

30mm 

screw

8

11

7

A

B

11

8

7

B

A

1!

2!

Pre drill 

hole

1!

2!

Pre drill 

hole

Summary of Contents for 02PLAY511511-V2-PEFC

Page 1: ...y hard surface BUILDING A BASE Ensure the base is level and is built on firm ground to prevent distortion checking with a spirit level Refer to diagrams for the base dimensions The base should be slightly smaller than the external measurement of the building i e The cladding should overlap the base creating a run off for water It is also recommended that the floor be at least 25mm above the surrou...

Page 2: ... V2PG AI 02PLAY511511 V2WS 5 6 4 Floor Door QTY x5 Window AI 02PHOW V1 AI 02PLAY511511 V2F AI 02PLAY511511 V2D 7 8 9 10 Small Roof Large Roof Window Cross Window Shutters PI 03 0036 QTY x2 QTY x2 PI 04 0013 QTY x5 QTY x4 AI 02PHWS V1 PI 03 0035 13 14 15 Roof Purlin 1721mm Cover Trim 1200mm Fascia Board 540mm Fascia Board 686mm Roof Eave 1835mm 11 12 F2732 1835mm F2744 1721mm S1256 1200mm FAS1260 5...

Page 3: ...portation blocks from the bottom of each panel Take care removing the blocks as to not damage the panels Tap with a flat headed screwdriver and hammer Dispose of the blocks once removed Ply Door Stop PLY TRIANGLE T Hinge PI 07 0113 QTY x2 PI 07 0011 Window Block QTY x10 30mm Screw x 90 50mm Screw x 30 60mm Screw x 2 20mm Screw x 25 40mm Screw x 25 Felt Tacks x 120 30mm Black Screw x 14 Nail Bag Wo...

Page 4: ...30mm screw 6 19 A B A B 19 6 A 19 30mm screw Step 2 Parts needed x2 To fix the Door No 5 into the Door Gable No 1 Lay the Door panel flat on the ground and place the Door within the doorway Ensure you leave a 12mm gap on each side of the Door It is important that the door is placed central in the space provided Use a 12mm strip to help keep the gap at 12mm The door can be hung from either side to ...

Page 5: ...lding to the floor until the roof is fitted 3x50mm Screws 50mm screw 3 2 3 2 1 Step 5 Parts needed Fix Door Gable No 1 and Window Side No 3 using same method shown in the previous step Position the panels so there is equal spacing between the floor and cladding on all four sides Before fixing the door gable check the top and bottom of the door and remove any transit screws Make sure door opens and...

Page 6: ...ew per end Screw through the outside of building into into framing We recommend finishing framing surfaces with sand paper to remove any splinters 6x70mm Screws 70mm screw 12 12 Step 7 Parts needed x2 x2 x2 Screw the Roof Eaves x2 No 11 on to the bottom of both Large Roof sheets No 7 using 3x30mm screws per eave Fix the Roof Sheets No 7 No 8 straight into the rafter using 6x30mm screws per Small R...

Page 7: ...ts 16x50mm Screws 50mm screw Step 9 Cut Felt into 3 sheets of 1959mm and lay onto roof as shown in diagram ensuring there is a 50mm overhang around the sides Fix using felt tacks at 100mm intervals 120xFelt tacks Felt tacks Step 10 Parts needed x4 Fix the Cover Trim x4 No 13 to each corner of the building as shown using 3x30mm screws per trim 12x30mm Screws 30mm screw 13 13 13 1 2 Pre drill hole 1...

Page 8: ...nst the inside of each window Position the frame centrally to the window and fix using 4x20mm screws per frame Place the Wooden Door Handle No 18 on the outside of the door and use a 60mm screw from the inside to secure On the inside of the door opening fix the Ply Triangle No 16 door stop to the bottom left corner using 3x20mm screws Fix two Window Shutters No 10 to each side window with 4x30mm s...

Page 9: ...ed that the following checks and maintenance are carried out at the begin ning of each season as well as at regular intervals during the usage season Check all nuts bolts screws for tightness and tighten when required Check for movement opening of wood giving rise to protrusion of nail heads and tips Check hinges Replace defective parts in accordance with the manufacturers instructions Check any c...

Reviews: