SAFETY PRECAUTIONS 

Rev 2.0 

 

 

Please observe the following general safety precautions carefully before and during all phases of 

handling, installation, removal, operation and maintenance of this appliance. Failure to comply with 

these precautions violates safety standards of design, manufacture and intended use of the product. 

Mercator Lighting assumes no liability for customer’s failure to comply with these requirements. 
 

SAFETY WARNINGS 

1.

 

Read all instructions and safety information. Review assembly diagrams provided before 

installing your new ceiling fan. 

2.

 

This fan must be installed by a licensed and qualified electrician according to SAA and 

local authority regulations. 

3.

 

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for 

their safety. 

4.

 

Young children should be supervised to ensure that they do not play with the appliance. 

5.

 

All electrical works must only be undertaken after disconnection of the power by 

removing fuses or turning off the circuit breaker, to ensure all pole isolation of the 

electrical supply. 

6.

 

Do not use outdoors where it could be exposed to water or moisture. 

7.

 

This manual is not intended to instruct or assist untrained or unqualified persons to install this 

ceiling fan. 

8.

 

It is the responsibility of qualified, licensed installer and user to apply common sense 

and care at all times during installation and operation. 

 

HOW TO CHOOSE A PROPER LOCATION FOR CEILING FAN 

1.

 

According to regulations and to provide a safe clearance from the floor, the lowest point on the 

fan blade must be at least 2.1 metres (7 feet) from the floor. 

2.

 

For fan installed enclosed outdoors, the fan must be installed at least 1.5m from the perimeter 

of roof/eaves of the enclosure to protect the product from direct or indirect rain water or 

sunlight. 

3.

 

Please check carefully and make sure that ceiling joists are strong enough and of adequate size 

to support the weight of about 35 kg. 

4.

 

To reduce the risk of fire, electrical shock or personal injury, please make sure that the fan 

mounting bracket is directly supported from the building structure. Do not mount to an outlet 

box. 

5.

 

The mounting bracket must be firmly screwed to a load bearing building structure e.g. a 

concrete ceiling, steel structure, or a timber frame. If additional timber frames are to be added, 

those must be securely nailed or screwed between the beams. 

6.

 

Attach fan blades after the fan motor housing is installed and properly secured. Keep the fan 

motor and blades in the original package until it is ready to be installed. 

7.

 

Check and confirm, after the fan is completely installed, that all connections are proper and 

secure to prevent the fan from falling or causing property damages or personal injury. 

Summary of Contents for FC180124BC

Page 1: ...ult in slight variations between the product illustrated and that which is contained within this package THE QUALITY BRAND IN FANS INSTALLATION AND OPERATION INSTRUCTION BOOK REV 2 0 GLENDALE SERIES M...

Page 2: ...ON 1 SAFETY PRECAUTIONS 2 UNPACKING YOUR CEILING FAN 4 FAN INSTALLATION INSTRUCTIONS 5 WALL CONTROLLER INSTALLATION INSTRUCTIONS 6 WIRING DIAGRAMS 7 INFORMATION FOR LICENSED ELECTRICIAN AND FAN OWNERS...

Page 3: ...A WARNING CAUTION notice denotes a hazard It calls attention to an installation procedure operating procedure maintenance procedure or the like that if not correctly performed or adhered to could res...

Page 4: ...ct or assist untrained or unqualified persons to install this ceiling fan 8 It is the responsibility of qualified licensed installer and user to apply common sense and care at all times during install...

Page 5: ...an unapproved wall controller voids the warranty Only Mercator wall controllers are approved for use with Mercator ceiling fans Do not use solid state wall controllers 11 This fan is compatible with...

Page 6: ...away the carton or other packaging material as it may be needed if warranty replacement or repair is ever necessary 1 x Hanger Bracket 4 x Blades 1 x Pre assembled Fan Motor HARDWARE BAG INSTRUCTION...

Page 7: ...ing plate of the blade fixing hole Insert blades one at a time through four slots around the fan housing and secure with three screws for each blade through the top opening Repeat this procedure for a...

Page 8: ...is turned off at the main power box before commencing work Turn off the power by removing fuse or turning off circuit breaker before installing the wall controller HOW TO INSTALL WALL CONTROLLER 1 Di...

Page 9: ...ONTROLLED WITH WALL CONTROLLER ONLY install the wall remote controller kit that comes supplied or recommended by MERCATOR DO NOT control operation of fan or light with wall controllers other than thos...

Page 10: ...LLED WITH REMOTE CONTROLLER OPTIONAL ONLY install the wall remote controller kit that comes supplied or recommended by MERCATOR DO NOT control operation of fan or light with wall controllers other tha...

Page 11: ...light fitting version with light II Re tighten all screws on fan blades do not over tighten III Re tighten all screws in the hanging bracket and covering plate 3 MECHANICAL NOISE I Let the fan run fo...

Page 12: ...ed spinning before changing the summer winter switch Summer setting marked SUMMER Fan turns in counter clockwise direction A downward airflow creates a cooling effect This also allows you to set your...

Page 13: ...ould spin in anti clockwise direction so cool air is blowing down producing a cool breeze In winter reverse the switch fan should spin in clock wise direction so that an upward airflow will push warm...

Reviews:

Related manuals for FC180124BC