20-07437-01

9

ADJUSTMENT OF COXIT FLAPS
Control

1.  Loosen, adjust to the required angle and then 

tighten the knob.  

2.  Turn the knob to raise/lower the flap.

There are two types of adjustmets for the coxit flaps:

On chairs with no seat angle adjustment (1) the 

adjustment knobs are placed under the front edge of the 

seat.
On chairs equipped with seat angle adjustment (2) the 

adjustment knobs are placed on the back edge of the 

seat.

2

1

CHARGING

ROTATION ACCESSORY (OPTIONAL)
Control

1. Turn clockwise to disengage, anticlockwise to lock.

Note!

 Rotation should be in locked position when sitting 

down and standing up from the chair. Make sure that the 

lever has clicked into place.

1

USER MANUAL

Battery charger 2240-24V (part no. 805021) must be used to charge the chair. If using a different charger or different 

batteries to those which are provided alongside the product by Mercado Medic AB, the warranty and Mercado Medic 

AB’s product liability will cease to be valid for any cases regarding the battery, charging or other electronic aspects of 

the chair. The battery should be charged on a daily basis. Fully charging the battery on a daily basis will take between 

2–6 hours. In order to preserve the battery’s service life, it is important that it never becomes fully discharged as 

this can damage the battery cells. If the chair is equipped with a hand control with cord, the battery level can be 

identified by checking the indication lights (1). On a full charge with a high electrical lifting mechanism, you can raise 

the chair fully up/down up to 120 times with a load of  

80 kg(176 lbs), or up to 90 times with a load of 150 kg(330 lbs).

How to charge the chair

Connect the contact plug (2) on the charger to the charging outlet (3) (the charging outlet is placed under the seat at 

the rear on the right side). Then plug the charger into a wall socket. The LED on the charger will indicate that charging 

is underway. When the LED changes colour from orange to green, the battery is fully charged. None of the electrical 

functions will work while the chair is charging. The chair must be charged in a safe manner. For this reason, choose a 

wall socket that is easily accessible to plug the charger into. The charger’s cable is 1.8 m and must not be extended. 

In case of emergency, disconnect the chair by unplugging the charger from the wall socket. Do not sit on the chair 

when it is charging. 

3

2

A.  Charging is 

required

B.  Battery Level
C.  Warning light  

(internal error/ 

button lock)

1. Indication lights

2. Contact plug

3. Charging outlet

1

A

B

C

Summary of Contents for REAL 9000 PLUS ADULT

Page 1: ...lls of products and accessories We reserve the right to make changes to this manual and its contents ADULT REAL 9100 PLUS CHILD MINI REAL 9400 PLUS COXIT REAL 9800 PLUS TABLE OF CONTENTS Assembly for...

Page 2: ...20 07437 01...

Page 3: ...mechanism 4 5 5 Standard backrest mechanism 5 5 4 3 6 6 For manual brake remove the chair from the cardboard box Remove the brake lever that is held in place with plastic wrap along the brake shaft a...

Page 4: ...maximum 2 minutes every 20 minutes The electronics in the chair measure the activity and shut down the electrical functions if this limit is exceeded Only electrical equipment from Mercado Medic AB ma...

Page 5: ...chanism should be checked regularly for dust dirt and stability Raise the seat to its highest position Clean with a cloth Do not use any water or solvents Then lubricate the cylinder using a thin shee...

Page 6: ...in workmanship or material The warranty only applies to the original purchase and terminates if you transfer modify or sell the product Warranty period Welded metal parts 10 years Gas springs and ele...

Page 7: ...l 1 Seat tilt Crank adjustment turn the knob 2 Seat tilt Gas spring pull the lever backwards 3 Seat tilt Gas spring pull the lever upwards 4 Seat tilt Electric pull the lever upwards downwards 5 Seat...

Page 8: ...laced here move with the seat tilt 2 Armrests placed here do not move with the seat tilt 3 There are 3 positions When position 3 is selected the chair must be equipped with base extensions 1 Forwards...

Page 9: ...hours In order to preserve the battery s service life it is important that it never becomes fully discharged as this can damage the battery cells If the chair is equipped with a hand control with cor...

Page 10: ...once a day The battery may only be changed by personnel authorised by Mercado Medic AB See assembly instructions Battery Replacement Troubleshooting for electrical functions on your chair There are n...

Page 11: ...20 07437 01...

Page 12: ...ler in North America EMP Living LLC 14941 NE 147th CT Woodinville WA 98072 Phone 425 949 7195 Email info empliving com Web www empliving com Mercado Medic AB Phone 46 0 8 555 143 00 14 Tryffelslingan...

Reviews: