ground level with the doors open), the car alarm should be disabled so as to avoid false alarms due to 

vandalism.  

For this case, the emergency telephone MMk-656 has an input at the pair of terminals 

J1 FILTR

 

and 

J1 FILTR

. When this input is short-circuited, generation of alarms from the car is disabled. 

 

7.

 

CONNECTORS 

To locate the connectors, see the wiring diagram in section 14. 

7.1.

 

Switches (J1) 

At the J1 connector, two different switches can be interconnected. These can be 

configured either as switches of type normally open (NO) or normally closed (NC), to effect 
which the following command should be used 

*12#

- At the pair of terminals 

J1 ALC

 and 

J1 ALC

 the car alarm is connected. 

- At the pair of terminals

J1 FILTR

 and 

J1 FILTR

, activation of alarm filtering can be connected. 

When this input is closed, generation of alarms from the car is disabled. This functionality is 

required by the standard EN 81-28 and permits disconnection of the alarm when the car is not 
capable of trapping persons. 

- At the pair of terminals 

J1 SOS/EOA

 and 

J1 SOS/EOA

 the switch to generate a maintenance 

alarm for the operators, which generates a call to the number stored in register 01 of the 
telephone memories, can be connected. This possibility is included so that maintenance 

personnel have a direct line in the event of problems, which is totally independent of the 
conventional car alarm. It is possible to install various generation points in parallel without 

any problem. This switch is not affected by alarm filtering. 

Should there be an alarm open, this same switch also serves as the alarm clear switch, 

for activation once rescue has taken place, as required by European standard EN 81-28. 

 - At the pair of terminals 

J1 AUX OUT

 and 

J1 AUX OUT, 

an LED indicator may be connected, or a 

relay activated, depending on the application, with a maximum permitted power of 1W at 12V. 

This output performs different functions according to how it is programmed by means of the 
parameter 

*28

: it can be activated if a cut in the electricity grid supply is detected, or it can be 

configured to generate an output pulse of duration 1 second on receiving a command. 

NOTE

: The switch terminals are only designed to connect switches, and not to supply 

other lift peripherals: connection of other devices could damage the equipment inputs. 

 

7.2.

 

Power supply (J2) 

The MMk-656 module is fed by the 

J2

 connector. The equipment supply tension is 10 Vdc 

- 30 Vdc. 

 

Connect the regulated power supply at the terminals 

J2 V+ 

(10-30 Vdc) and 

J2 V

- (GND). 

Summary of Contents for MMk-656

Page 1: ...INSTRUCTION AND CONNECTION MANUAL MMk 656 Compact Emergency Telephone for Lifts...

Page 2: ...prohibited Disclaimer The manufacturer declines any responsibility to the purchaser of this product and third parties for damages losses costs or work done due to accidents product misuse improper ins...

Page 3: ...TEST CALL EN 81 28 8 5 CLEARING AN ALARM EN 81 28 8 6 ALARM FILTERING EN 81 28 8 7 CONNECTORS 9 7 1 Switches J1 9 7 2 Power supply J2 9 7 3 RS 485 serial communications connector J3 10 7 4 Telephone...

Page 4: ...ally designed for lifts though any terminal at all ought to work This telephone permits programming of the set using its keypad guided by voice assistance MULTI CABIN Several modules up to the maximum...

Page 5: ...e as follows Automatic calling of up to 4 pre programmed numbers when an alarm is raised Automatic calling when a maintenance alarm is raised need to rescue operators or communicate with the centre Pe...

Page 6: ...dvice Possibility of interconnecting up to 4 sets on the same telephone line with no need for extra cabling Flush mounting in the panel with M6 through screws or using double sided adhesive Different...

Page 7: ...onnector Following an audible countdown in the car a call to the first number in the bank of registers dedicated to storage of alarm telephone numbers bank of registers 02 to 05 is initiated If commun...

Page 8: ...so programmed that when the equipment initiates a test call it configures itself to make the following call 24 hours later but should communication be correctly established with the server which atte...

Page 9: ...alarm for the operators which generates a call to the number stored in register 01 of the telephone memories can be connected This possibility is included so that maintenance personnel have a direct...

Page 10: ...V WARNING NEVER connect the mains supply to the battery terminals 7 3 RS 485 serial communications connector J3 Communication with the control system or other devices such as the graphical viewer may...

Page 11: ...o have a point for audio and alarm generation alternative to that of the main unit Interconnection with this external module is by means of the RJ 45 terminals J6 For this a male male RJ 46 cable shou...

Page 12: ...rwritten by those from the SD card The set plays a message confirming that it has been updated The file CONFIG CFG is not found on the SD card One is created on the SD card using the previous paramete...

Page 13: ...ured as in the following table Cabin 1 Cabin 2 Cabin 3 Cabin 4 Switch 3 ON OFF ON OFF Switch 4 ON ON OFF OFF Table 1 Car selection switches 8 STATUS LED General status information for the equipment is...

Page 14: ...eter programming and for playing the car announcements In the case of playing car messages up to 4 different languages can be selected to be played consecutively For example the countdown message play...

Page 15: ...ll NOT be possible to receive incoming calls If two cars are programmed with the same number it will NOT be possible to communicate between them and so neither will it be possible to reconfigure them...

Page 16: ...easurement cycle To do this it is necessary to issue the command 91 or its equivalent in PC mode Once this command has been entered and the programming process has been completed hang up the intercom...

Page 17: ...ration 3 Wiring diagram for the MMk 656 15 RS 485 SERIES CHANNEL The J3 input corresponds to an RS 485 series channel The port configuration is 9 data bits without parity and one Stop bit 9N1 at 4800b...

Page 18: ...t of frame Data Includes the code of the commands and the data necessary for their execution CHK Checksum of 7 bits of the field Data Calculation of the XOR of all the bytes of the frame except STX an...

Page 19: ...These are the messages which it is desired to reproduce in the module of the lift car and they are generated from the combination of messages in the following table Sint 1 Message Sint 1 Message Sint...

Page 20: ...ice message table Messages are formed by combining a message from each of the columns For instance to build the phrase Floor One choose Floor from the first column Silence from the second and One from...

Reviews: