85-03-01205
ML-SERIES FIREPLACE
Page
54
4.8
NATURAL GAS TO LPG CONVERSION
A natural gas to LP gas conversion kit must be ordered and installed in this fireplace to burn LP gas.
LP conversion kit contains the following parts: one motorized LP pressure regulator #907.012, one cap orifice ,
an L-shaped Torx
wrench and a LP conversion label.
4.8.1
Procedure to Convert Fireplace for LP Gas
4.8.1.1
Converting the Burner Orifice
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, it is highly recommended that you
convert this fireplace and its pressure regulator, pilot natural gas/LP clip position and burner orifice prior to placing this
fireplace in its fireplace cavity.
Follow the step below to prepare this fireplace for conversion to LP gas:
1.
Remove the glass frame. Directions to remove the
glass frame are in this manual. See section “TO REMOVE DOOR”
2.
Remove the floor plate from the fireplace. On the ML39 & ML47 the floor plate goes around the pilot. When lifting the floor
plate be careful to lift it straight up past the pilot hood. Then hold the floor plate at an angle to get it through the front opening
of the fireplace.
3.
Next remove the burner from the fireplace. Remove the two screws from each end of the burner. Then slide the burner to the
left to remove it from the air shutter box. The burner will then be free and can be removed from the fireplace.
MODEL
ML39
ML47 ML54 M60
ML72
LP Kit Part #
HA-96-00023
HA-90-00110
HA-112-00061
ORIFICE SIZES
(0-2000 ft)
#50 L.P.
#48
L.P.
#49 L.P.
#46F #54R L.P.
ORIFICE SIZES
(2000-4500ft)
#51 L.P.
#49 L.P.