11
16" MIN.
FROM GLASS FRAME EDGE
TO PERPENDICULAR SIDE WALL
-A-
12" MIN
FROM TOP EDGE OF TOP
CONVECTION AIR OPENING
TO BOTTOM OF 8" DEEP MANTEL
18 1/16
29 3/16
VISIBLE GLASS SIZE = 398 SQ. IN.
ACTUAL GLASS SIZE = 468 SQ. IN.
-B-
22 3/16
30 3/8
15 3/4
16"
HEARTH PROTECTION PAD REQUIRED IF NOT ELEVATED.
FOR EVERY 1-INCH THE UNIT IS ELEVATED, HEARTH
PROTECTION PAD DEPTH MAY BE REDUCED BY 2". IF ELEVATED
6" OR MORE, NO HEARTH PROTECTION PAD IS REQUIRED.
8.0
12
1
1
0
4
5
6
7
8
9
10
11
12
7 6 5 4 3 2 1 0
8
APPROVED
MANTEL
PROFILES
MANTEL DEPTH (IN.)
FIREPLACE FACE MUST BE COVERED W/
NONCOMBUSTIBLE FACING IN THIS AREA.
A COMBUSTIBLE MANTEL ONLY ALLOWED IN
THIS AREA IF INSTALLED OVER
NON-COMBUSTIBLE FACING MATERIAL.
4" NON
COMBUSTIBLE
MENDOTA FV33-M GAS DIRECT VENT FIREPLACE INSERT
SPECIFICATIONS & CLEARANCES
FV33-M Faceplate Dimensions
A B
Inches
mm.
Inches
mm.
No Trim
24
610
36
915
Is available
27
686
40
1016
For FV33-M
31
788
44
1118
Minimum
Fireplace
Opening
Required
30
‐
3/8”
wide
X
18
‐
3/8”
high
X
15
3/4”
Deep