14
14.
Remove the Vent Adapter by removing two
5/16” Hex Bolts and sliding Vent Adapter to-
wards rear of Insert.
15.
Tightly secure 3” and 4” flex vents with
clamps provided. Seal vent cap/flashing to
top of chimney with weatherproof sealer.
Seal areas between flex pipes and existing
chimney, at damper area, with unfaced fiber-
glass insulation.
16.
Carefully slide Insert into the fireplace open-
ing (Note: Plug in the AC Power cord to a
110 volt AC receptacle inside the fireplace
opening or extend it out and connect to a
grounded wall outlet.
17.
Slide Vent Adapter forward between guide
rails. Vent Adapter’s front flat section should
contact insert top as you slide the Vent
Adapter forward.
18.
Use Glass Latch Tool to grab Vent Adapter
through slot and hole provided. As you apply
downward pressure, pull Vent Adapter forward until front flange on Vent Adapter is about ½” away from
front lip on Insert.
19.
Slide 5/16” Hex Bolts through holes in face of Insert and start one Bolt in each of the two press nuts on
Vent Adapter Flange. Using a 5/16” Hex Hand Driver, tighten the hex bolts a few turns at a time alternat-
ing between the two hex bolts until the screws are hand tight and vent adapter is pulled fully forward.