Chimney Connec�on
In order for the stove to perform sa�sfactorily the chimney height must be sufficient to ensure an adequate
draught to clear the products of combus�on and prevent smoke problems into the room.
NOTE:
A chimney height of not less than 4.5 metres measured ver�cally from the outlet of the stove to the
top of the chimney should be sa�sfactory. Alternately the calcula�on procedure given in BS 5854:1980 may
be used as the basis for deciding whether a par�cular chimney design will provide sufficient draught.
Stove Performance & Tes�ng
Ashco� Wide is tested in accordance with EN 13240. It is recommended as suitable for use in smoke control
areas when burning wood logs and when fi�ed with a mechanical stop to prevent closure of the secondary
air control beyond :
Output
Range kW
CO@13%
Par�culate ma�er
@13% mg/nm3
Nox @13%
CxHy@13%
2022
Compliant
Woodland DS
6-9
0.08(W)
20
116
109
YES
Tested Gas flow rates flue
gas temperatures
Flue gas flow rate
Wood
Test Flue gas Temperature
wood /coal
Pascals Pressure
Woodland DS
7.2 g/sec
310 Deg C
12pa
Log Length
Wood Reload
Weight wood
load
Length
SE dimensions
LxWxD cm
Logs
Woodland DS
35cm
25x14x11
2
1hr
1.8kg
Output
Wood
Efficiency
wood
Recommended for
smoke control
Mechanical air
stop for SE Model
Mechanical stop 10mm
from closed posi�on.
Woodland DS
8.0kW
75.7%
YES
YES
10mm
Distance to Combus�ble materials
Combus�ble materials should not be located where the heat dissipa�ng through the walls of fireplaces or
flues could ignite it. Therefore when installing the stove in the presence of combus�ble materials due
account must be taken of the guidance on the separa�on of combus�ble material given in Building
Regula�ons Approved Document J and also in these stove instruc�ons. The minimum distances to flammable
materials are specified on the EN 13240 plate on the back of the stove
Distance to combus�bles rear /
Front
Distance to combus�bles sides
Suitable for 12mm hearth
N/A
200mm
YES