WOODLAND DOUBLE SIDED & WOODLAND DOUBLE

SIDED LOG STORE MODEL PEDESTAL

The Woodland Double sided Catalyst

- M00730-00-00-00-00

The Woodland Double sided Logstore Catalyst

- M00733-00-00-00-00

Oct 2019 V1

Summary of Contents for The Woodland Double sided Catalyst

Page 1: ...n et Mode d Emploi MULTI FUEL SMOKE EXEMPTION MODELS WOODLAND DOUBLE SIDED WOODLAND DOUBLE SIDED LOG STORE MODEL PEDESTAL The Woodland Double sided Catalyst M00730 00 00 00 00 The Woodland Double side...

Page 2: ...nc la poign e C3 325 mm 325mm FLUE OUTLET DIAMETER Diam tre du conduit de fum e D 125 mm 125 mm CENTRE OF FLUE TO FRONT OF STOVE Centre de la sor e de fum e et l arri re du po le E 215mm 215mm CENTRE...

Page 3: ...ons are detailed in the Warranty Statement on the Eurostove website www eurostove co uk In the event of any conflict of informa on the wording on the website shall prevail Important Note Should any p...

Page 4: ...larm must be fi ed in the same room as the appliance Further guidance on the installa on of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instruc ons Pro...

Page 5: ...plate allowing enough room to drill a hole through the flue collar and into the flue pipe 3 Secure the collar and flue pipe with a suitably sized self tapping screw Woodland DS Catalyst Converter The...

Page 6: ...xempt models with a 125mm collar burning wood only can be installed on a flue of 125mm throughout Any bend in the chimney or connec ng flue pipe should not exceed 45 90 bends should not be used other...

Page 7: ...ng Notes 1 The weather surface is the building external surface such as its roof les or external walls 2 A flat roof has a pitch less than 10 3 The clearances given for A or B as appropriate will also...

Page 8: ...08 W 20 116 109 YES Tested Gas flow rates flue gas temperatures Flue gas flow rate Wood Test Flue gas Temperature wood coal Pascals Pressure Woodland DS 7 2 g sec 310 Deg C 12pa Log Length Wood Reloa...

Page 9: ...proved Document J and also in these stove instruc ons The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove HEARTH The hearth should be able to acco...

Page 10: ...lts at the foot of the stove leg Posi on the Logstore legs and use the levelling feet to secure them to the body of the stove Use a spanner or a socket wrench to fully ghten Right the stove and see if...

Page 11: ...r of the stove The air control on the Woodland DS Model has 40mm travel on the air control The SE fixing is designed to prevent the air supply of the stove from being completely shut off this promotes...

Page 12: ...use hold waste DO NOT EXCEED SPECIFIED FUEL WEIGHTS DO NOT BURN HOUSE COAL DO NOT BURN HOUSEHOLD WASTE THIS APPLIANCE IS NOT AN INCINERATOR LIGHTING YOUR STOVE FOR THE FIRST TIME Before ligh ng your s...

Page 13: ...oxic firelighters place one or two small dry split logs split on top Kindling stacked as in diagram allows combus on air flow freely and will aid igni on 2 Posi on the Universal Air Control UAC lever...

Page 14: ...lsh Ministers Further informa on on the requirements of the Clean Air Act can be found here h ps www gov uk smoke control area rules Your local authority is responsible for implemen ng the Clean Air A...

Page 15: ...tove requires a permanent air vent to the room This is to provide adequate air supply in order for the stove to operate safely and efficiently In accordance with current Building Regula ons the instal...

Page 16: ...a The firewood may be too wet b the intake of secondary air may be insufficient c fire not hot enough 4 The stove fails to heat fully a The firewood may be too wet b the intake of secondary air may be...

Page 17: ...fuel residues To enable a good flow of air through the appliance to reduce condensa on and subsequent damage leave the air controls fully open It is important that the flue connection any appliance ba...

Page 18: ...rts likely to be hot when the stove is in use Your stove has the following parts in the stove 1 Cast Iron grate log retainer 2 Ashpan 3 Stove Glove 4 Top plate decora ve cover plate 5 Instruc on manua...

Page 19: ...come out easily Re rez les briques d flectrices en re rant 8 goupilles en acier des parois lat rales Les briques d flectrices vont maintenant sor r facilement r 3 Remove side bricks Enlevez les brique...

Page 20: ...DOOR ASSEMBLY ECLATE DE PORTE To find out more details as well as to get prices and availability of these parts please visit www eurostove co uk the woodland furnace door Woodland Double sided Handle...

Page 21: ...8 1 1 1 316 477 25 Poz slo v kresu N zev 1 EST_45051_2018_010_03_1 deflektor M 2 EST_45051_2018_010_01_2 bok M 1 316 477 25 316 340 8 1 1 1 316 Schv le Poz slo v kresu N zev Materi l Polotovar Konfi 1...

Page 22: ......

Page 23: ......

Page 24: ...endip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www mendipstoves co uk Email info eurostove co uk Telephone 01934 750 500 Part of the Eurostove Group Woodland Double sided Ma...