background image

OPERATING YOUR STOVE - SUITABLE FUELS - LOXTON 3

COMBUSTION AIR

CONNECTION TO CHIMNEY

COMMISSIONING AND HANDOVER

Mendip Stoves are factory set up with a top flue outlet, this can be altered from top to rear connec�on, remove

the top collar and rear cover plate and exchanging collar and plate. Care should be taken to ensure an air�ght

fit when refi�ng collar and plate. A decora�ve cover plate is included with every stove to cover the hole in the

convec�on top plate. This collar allows connec�on to either a masonry chimney or a prefabricated factory made

insulated metal chimney.

6 of 24

INSULATED CHAMBERS

In order for the stove to perform efficiently and safely there should be an adequate air supply into the room

in which the stove is installed to provide combus�on air. This is par�cularly necessary if the room is double-

glazed or a flue draught stabiliser is opera�ng in the same room as the appliance. The provision of air supply

to the stove must be in accordance with current Building Regula�ons Approved Document J. An opening

window is not appropriate for this purpose. Air inlets must be posi�oned in such a way that they cannot be

blocked. An air inlet may be a vent (the vent must be open and the capacity for the vent sufficient when the

stove is lit). There are no European rules regarding the minimum distance to non-flammable walls, Mendip

Stoves recommend leaving a minimum distance of 50mm to non combus�ble walls, but preferably a distance

of 10 cm is be�er for heat distribu�on.

Ensure loose parts are fi�ed in accordance with the instruc�ons given in the instruc�on booklet. On

comple�on of the installa�on allow a suitable period of �me for any fire cement and mortar to dry out, a

small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emi�ed

safely into the atmosphere. Do not run at full output for at least 24 hours. On comple�on of the installa�on

and commissioning ensure that the opera�ng instruc�ons for the stove are le� with the customer. Ensure to

advise the customer on the correct use of the appliance with the fuels likely to be used in the stove and

no�fy them to use only the recommended fuels for the stove. Advise the user what to do should smoke or

fumes be emi�ed from the stove. The customer should be warned to use a fireguard to BS 8423:2002 in the

presence of children, aged and/or infirm persons.

The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not

independently supported.

Mendip stoves have been tested and are suitable to be installed on a 12mm non combus�ble plate such as

12 mm glass plates . Installa�on of all hearths should comply in size and construc�on so that it is in accordance

with the provisions of the current Building Regula�ons Approved Document J.

The clearance distances to combus�ble material beneath, surrounding or on the hearth and walls adjacent to

the hearth should comply with theguidance onthe separa�onof combus�blematerial givenin BuildingRegula�ons

Approved Document J and also in these stove instruc�ons.

If the stove is to be installed on a wooden floor, it must be covered with a non-combus�ble material at least

12 mm thick, in accordance with Building Regula�ons Approved Document J, to a distance of 30 cm in front of

the stove and 15 cm to each side measuring from the door of the combus�on chamber.

HEARTH

The Mendip Loxton 3 model is tested to burn wood or smokeless coal. and wood brique�es . For a full list of
suitable fuels, check with the official solid fuels approvals body, HETAS or Solid Fuel Associa�on. Do not
overload stove as this can cause excessive heat and damage the stove( see table on page 4).

ALWAYS KEEP FUEL LOAD BELOW TERTIARY PORTS AT REAR OF STOVE.

Only use fuels approved for use on hea�ng stoves.

Do not burn liquid fuels, dri� wood, finished wood, sawn wood, pallet wood, chipboard/plywood,

varnished wood or plas�c coated wood, wood treated with preserva�ves, or house hold waste.

DO NOT EXCEED SPECIFIED FUEL WEIGHTS.

DO NOT BURN HOUSE COAL or PETROLEUM COKE. DO NOT BURN HOUSEHOLD WASTE, THIS APPLIANCE IS NOT AN

INCINERATOR. MENDIP STOVES RECOMMEND THE USE OF A FLUE THERMOSTAT TO CHECK YOUR STOVE IS NOT

OVERHEATING. PLACE FLUE THERMOSTAT DIRECTLY ABOVE COLLAR OF STOVE AND REFER TO TEMPERATURE GAUGE ON

PAGE 4.

Mendip Stoves are lined with vermiculite heat deflec�on panels and baffles, these panels are designed to

ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles

should not be removed other than for cleaning the stove. Any defec�ve panels should be replaced, cracks

less than 2mm wide are not classed as a defect. Place fuel carefully in fire chamber of your stove, impact

from logs can damage these panels

.

Summary of Contents for Loxton 3

Page 1: ...1 of 24 OPERATION AND INSTALLATION MANUAL Mul fuel and SE models Loxton 3 MK3 October 2020 V2 ENG FR Guide d u lisa on et Mode d Emploi...

Page 2: ...ict of informa on the wording on the website shall prevail Important Note Should any problems be experienced with your product claims must first be submi ed to the Retailer where the appliance was pur...

Page 3: ...in BS EN 50292 2002 and from the alarm manufacturer s instruc ons Provision of an alarm must not be considered a subs tute for either installing the appliance correctly or ensuring regular servicing a...

Page 4: ...red due to the difference in combus on between the stove and the open fire If there is no exis ng chimney then either a prefabricated block chimney in accordance with Building Regula ons Approved Docu...

Page 5: ...ce of 100mm will give a be er heat output All non combus ble walls closer than 100mm to the stove should be at least 75mm thick For prac cal reasons the back wall of the fireplace recess and the heart...

Page 6: ...should be warned to use a fireguard to BS 8423 2002 in the presence of children aged and or infirm persons The hearth should be able to accommodate the weight of the stove and its chimney if the chimn...

Page 7: ...YOUR WOODBURNING STOVE To re fuel your stove in the cleanest way Only refuel your stove when flames have died down and you have glowing embers Before refuelling open secondary air slider fully Open do...

Page 8: ...m the logs fully established close the secondary air supply to the low output se ng When opera ng at high output secondary air set fully open the new refuel charge does not require any boost air to es...

Page 9: ...and air dried under cover for two years before being used as firewood Do not burn liquid fuels dri wood finished sawn wood pallet wood chipboard plywood varnished wood or plas c coated wood wood trea...

Page 10: ...hot for over 24 hours Ash must be stored in a non combus ble container and must not be mixed with other combus ble waste Prolonged non use summer If the stove is to be le unused for a prolonged perio...

Page 11: ...s are flammable and therefore dangerous to use around a lit stove Do not use aerosols sprays near a lit stove The use of any aerosol is dangerous and care must be taken in handling aerosols Warning No...

Page 12: ...nded fuels listed above nor does it cover instruc ons for the use of other fuels 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clear c that a...

Page 13: ...13 of 24 Loxton 3 Mk3 October 2020 onwards par r d octobre 2020 1 1 21 3 10 7 9 11 12 6 13 17 18 16 15 19 20 4 5 15 2 14 8 23 22 22 2...

Page 14: ...sures AVERTISSEMENT IMPORTANT Ce po le ne doit pas tre install dans une chemin e servant d autres appareils de chauffage La pi ce o est plac le po le ne doit pas tre quip e d un disposi f d extrac on...

Page 15: ...nner le poele de fa on sa sfaisante la hauteur de la chemin e doit tre suffisante pour assurerun rage ad quat pour effacer les produits de combus on et de pr venir les probl mes de fum e dans la pi ce...

Page 16: ...n cessaire de pr voir avec le po le des entr es d air suffisantes pour un fonc onnement efficace pour assurer la s curit des habitants et parer toute ventualit Cela est par culi rement n cessaire si...

Page 17: ...n cessaires l u lisateur en cas d mana ons de fum es par le po le Le client doit tre aver de l u lisa on d un pare feu la norme BS 8423 2002 en pr sence des enfants ou de personnes g s ou infirmes FON...

Page 18: ...ige une pr sence intermi ente Ne le laissez pas marcher toute la nuit ou pendant de longues p riodes sans surveillance Le po le deviendra tr s chaud faites a en on U lisez le gant et les accessoires f...

Page 19: ...mani re la plus propre ne placez pas de combus ble dans votre po le lorsque les flammes se sont apais es ou que vous avez des braises Avant de faire le plein ouvrez l air pleinement et placer le levie...

Page 20: ...pl tement ouvert jusqu ce que le nouveau bois a pris et est en train de br ler puis fermer le tirette d air secondaire sa position op rationnelle De retour au po le dans la matin e le feu aura teinte...

Page 21: ...Non u lisa on prolong e d t Si le po le n est pas u lis pendant une p riode de temps prolong e par exemple pendant l t alors un ne oyage en profondeur pour liminer les r sidus de cendres et de carbura...

Page 22: ...moner la chemin e travers l appareil Si une chemin e a t u lis e pour une installa on de feu ouvert il est possible que la temp rature des gaz de combus on plus lev e par r d un appareil ferm puisse d...

Page 23: ...23 of 24...

Page 24: ...s Ltd 2019 MK3 ver 2 April 2021 Mendip Stoves Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 www mendipstoves co uk E mail info mendipstoves co uk COD...

Reviews: