Interference tests should also be carried out if there are other appliances close by that move air to the outside, such as
tumble dryers.
COMMISSIONING
Ensure all parts are correctly fitted, and that the stove is set for the correct fuel.
Check the operation of: the door catch (ensuring it holds the fire door tight); the bottom grate riddling mechanism
(using the tool supplied); the air regulator wheel; and the air wash control.
Test the flue draught. The minimum draught required is 0.04 in WG; the maximum allowed is 0.06 in WG.
Light the stove and allow to reach a steady burn before checking for fume leakage into the room; open the door and
carry out a spillage test.
Demonstrate the methods of operation to the end user. Explain the need for an annual service and regular
maintenance schedule. Record your details in the space provided at the rear of this manual.
Ensure these instructions are left in the end user's possession.