background image

 

 

 

 

 

 

 
 

 

 

 
 

 

 

 
 

Item # 

NAME 

Wire Identification  

DESCRIPTION / INSTRUCTION 

Auger Motor 

Wiring 

1x Black Wire, 1x White Wire  

Attach both spade connectors to their respective terminals on the 

top of the auger motor as indicated by the arrows shown above. 

RTD Wiring 

1x Orange Wire, 1x Brown Wire 

Attach both spade connectors to the leads extending from the RTD 

as shown above. 

Grounding Wire 

Green Wire 

The connection point for the ground is located directly below the 

auger motor on the vertical panel behind the auger motor. 

Ethernet Cable 

Black Cable with Ethernet End 

Attach the Ethernet cable to the terminal on the Wi-Fi card as 

shown. Ensure that the wiring does not interfere with the auger 

motor’s moving components. 

Igniter Wiring 

1x Red Wire, 1x White Wire 

Attach both spade connectors to the leads extending from the 

igniter. These leads will extend from the airbox and can be located 

in between the two fans. 

Fan Wiring 

1x Blue Wire w/ 2 spade ends, 

1x White Wire w/ 2 spade ends 

Attach BOTH blue spade connectors to 1 fan and then attach the red 

spade connectors to the other fan. 

MEMPHIS ELITE COMPONENT 

WIRING DIAGRAM

 

NOTE: ALL TWO WIRE PAIRS FOR A SPECIFIC COMPONENT ARE REVERSABLE  
Example: The auger motor wiring can have the either spade connector from 
its two wire pair attached to either terminal and the motor will function 
normally. 

RTD 

Auger Motor 

Igniter 

Wi-Fi Card 

Fans 