WHEN REPLACING EEPROM (MEMORY) IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 5 seconds before Power On.
C4-1
88 0A 62 63 43 14 34 09 51 38
+0 +1 +2 +3 +4 +5 +6 +7 +8 +9 +A +B +C +D +E +F
INI
B2 92 93 00 00 00 15 08 00
06 29 01 17 10 60 32 3A DA D7
28 29 2A 2C 2E 30 32 34 36 38
43 45 46 47 48 49 4A 4B 4C
30 66 00 40 00 10
00
10 9A A9 0F 94 3E 06 04
20 10 15 20 25 26 27
30 3A 3C 3E 40 41 42
40 44 4D 4E 4F 50 51 52
53 55 56 57 58 59 5A 5B 5C
63 64 66 69 6D 74 79 7C 7E 7F
50 54 5D 5E 5F 60 61 62
60 --- --- --- --- --- ---
3.
4.
5.
6.
7.
8.
The unit will now have the correct DATA for the new MEMORY IC.
Table 1
1.
2.
Fig. 1
ADDRESS is now selected and should "blink". Using the PLAY or STOP button on the remote, step through the
ADDRESS until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using PLAY or STOP until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
ADDRESS and DATA should appear as FIG 1.
INIT 00 83
0010
0003
POWER ON
PLAY/REC
ADDRESS DATA
Summary of Contents for MVT2135B D Series
Page 60: ...M5A3 04C K1X5006 SPEC NO O R NO ...
Page 130: ...M5A3 25A K215009 SPEC NO O R NO ...