![Memorex MVR2040A C Series Service Manual Download Page 27](http://html1.mh-extra.com/html/memorex/mvr2040a-c-series/mvr2040a-c-series_service-manual_1770162027.webp)
ELECTRICAL ADJUSTMENTS
CAUTION
When replacing IC's or transistors, use only specified
silicon grease (YG6260M).
(To prevent the damage to IC's and transistors.)
1-1: PG SHIFTER
CONDITIONS
MODE-PLAYBACK
Input Signal-Alignment Tape (JG001B)
INSTRUCTIONS
Read and perform this adjustment when repairing the
circuits or replacing electrical parts or PCB assemblies.
1. BASIC ADJUSTMENT
1.
2.
3.
4.
D2-1
Connect CH-1on the oscilloscope to TP1002 and CH-2
to TP4201.
Playback the alignment tape. (JG001B)
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
While pressing the CH UP button on the set, press the
STOP button on the set for more than 2 seconds. if the
indicator ATR disappear's, the adjustment is finished.
(Refer to Fig. 1-1-A, B)
6.5H
CH-1
CH-2
CH-1
CH-2
6.5H
Fig. 1-1-A
Fig. 1-1-B