4. Insert one end of the Anode Support into the anode button,
then the other as shown in Fig. 1-5.
5.
6.
Confirm that the Support is securely connected.
Put on the Rubber Cap without moving any parts.
DISASSEMBLY INSTRUCTIONS
CRT
Support
Fig. 1-5
2. REMOVAL OF DEFLECTION YOKE
(Refer to Fig. 2-1)
1.
2.
3.
4.
5.
Loosen the screw
1
.
Remove the Convergence • Purity Magnet in the
direction of arrow (A).
Loosen the screw
2
.
Remove the 3 Wedges.
Remove the Deflection Yoke in the direction of arrow
(B).
Wedge
Wedge
Deflection Yoke
Convergence •
Purity Magnet
2
1
(A)
(B)
Fig. 2-1
INSTALLATION
Install new Deflection Yoke in reverse steps of REMOVAL.
NOTE
After adjusting the purity and the convergence, fix the
screw
2
and lock the wedges.