ELECTRICAL ADJUSTMENTS
[ TV ]
OSD H
B
Fig. 2-8
A
2-12: SEPARATION 1, 2
Receive the stereo signal.
Connect the AC voltmeter to CP351 through stereo
filter (400Hz, 2KHz).
Activate the adjustment mode display of Fig. 2-1 and
press the channel button (7) on the remote control.
The Fig. 2-9 appears on the display.
Press the channel button (2) on the remote control.
Press the VOL. UP/DOWN button on the remote control
until the L/R output is minimum.
Press the channel button (3) on the remote control.
Press the VOL. UP/DOWN button on the remote control
until the L/R output is minimum.
1.
2.
3.
4.
5.
6.
7.
Fig. 2-9
1. LEVEL ADJ
2. SEPARASTION 1
3. SEPARASTION 2
4.
5.
6.
7.
8. 0. RETURN
2-13: VCO FREERUN
1.
2.
3.
Receive an 80dB monoscope pattern.
Connect the digital voltmeter between the TP201 and
the Ground.
Adjust the L205 until the digital voltmeter is 3.1
±
0.05V.
D1-3