background image

BASIC

page 24

16  Index

A

accessories  9
address  23
air changes  11
air slider  11
air supply  10
air valve  10
alarm indication  11
alarm symbol  14

C

CE conformity declaration  20
cleaning  18
construction, oven  10
customer service  23

D

DIN 12 880  14
display, temperature  11
display, timer  11
door  10
door handle  10

E

error messages  19

F

failure, supply  8. 19
fan  10
fan indication  11

I

initial start-up  5
installation facilities  9

L

limiter, temperature  14
load  5

M

main switch  11
maintenance  18
material quality  4, 7
medical product  4
monitor relay  14

N

normal operation  12

O

operating mode indication  11
operating mode selection  12
operating time  13
operation  10

P

Protection Class 1  14
protection devices  14
purpose, intended  4, 15
push/turn control  11

R

relay, monitor  14

S

safety notes  4
SET key  11, 12, 13
stacking  9
start-up, initial  5
steriliser cassettes  17
sterilisers  15
subframe  9
supply failure  8, 19

T

TB  14
temperature  11
temperature display  11
temperature limiter  14
temperature monitor  14
temperature probe  5
temperature setpoint  11
timer display  11
timer operation  13
transport  4, 5

W

wall bracket  9

Summary of Contents for INB200

Page 1: ...Universal ovens UNB 100 500 UFB 400 500 Sterilisers SNB 100 400 SFB 400 500 Incubators INB 200 500 Operating Instructions...

Page 2: ...BASIC page 2...

Page 3: ...operation 10 5 1 Operating the door 10 5 2 Controls and indications 11 5 3 Switching on 11 5 4 Setting air changes 11 5 5 Setting the temperature 11 6 Selecting the operating mode 12 7 Normal operatio...

Page 4: ...se Instructions are disregarded all claims under warranty guarantee and indemnification are excluded The right to technical modifications is reserved Dimensional details are not binding 2 1 Intended p...

Page 5: ...our accessories 3 1 Subframe accessory Oven model 500 can be mounted on a subframe 3 2 Wall bracket accessory Oven models 200 to 500 can be wall mounted using the wall bracket The wall bracket is fac...

Page 6: ...tion of inflammable gas air mixtures either within the oven chamber or in the immediate surroundings of the equipment Large amounts of dust or corrosive fumes inside the oven chamber or in the surroun...

Page 7: ...500 800 900 Max number of trays 2 3 3 4 5 Max load per tray kg 10 30 30 30 30 Total load per oven kg 20 30 30 90 60 Ambient conditions Ambient temperature 5 C to 40 C rH 80 max no condensation Overvol...

Page 8: ...re limiter TB Class 1 High grade PT100 temperature sensor Class A in 4 wire circuit Special equipment to be ordered separately as accessories subframe wall bracket sterilisation cassette 4 2 Material...

Page 9: ...0100 with FI protection circuit This product is intended to operate on a supply network with a system impedance Zmax at the transfer point building connection of 0 292 Ohm max The user has to ensure...

Page 10: ...gh ventilation slots 3 in the chamber side wall The fan 5 on the chamber back wall produces a large air throughput and a more intensive horizontal forced circulation compared with natural convection T...

Page 11: ...ET key and set the temperature setpoint with the push turn control After the SET key has been released the display briefly flashes the temperature setpoint The display then changes to the actual curre...

Page 12: ...l operation In this operating mode the oven operates continuously and heats and controls to the set temperature On the ovens UFB SFB the fan is running continuously Setting the temperature Hold down t...

Page 13: ...oven will remain switched on Setting the temperature Turn the push turn control clockwise until the temperature display is flashing Hold down the SET key and set the required temperature setpoint with...

Page 14: ...ter it has cooled down and after the fault has been rectified 9 2 Monitor relay In addition to mechanical temperature protection the oven is provided with an electronic monitor relay If a fault occurs...

Page 15: ...cabinet The operation of the MEMMERT hot air steriliser is also subject to the Standard DIN 58 947 Part 6 A few examples of the correct preparation for different medical products are summarised in th...

Page 16: ...e 180 C heating up time sterilisation time total sterilisation time Type of loading light medium heavy Steriliser size withoutfan withfan withoutfan withfan withoutfan withfan 100 0 45 h 0 45 h 1 30 h...

Page 17: ...tes The cassettes should preferably be so arranged in the steriliser that the hot air flow can pass readily through the air slots The load to be sterilised is placed into the steriliser cassettes wrap...

Page 18: ...bly qualified electrician MEMMERT products require little maintenance It is however recommended to lubricate all moving parts of the doors hinges and closure once a year or 4 times a year with continu...

Page 19: ...module faulty E 3 PT100 temperature probe faulty In case there is a fault on the oven please get in touch with an authorised service organisation or contact the MEMMERT customer service department Whe...

Page 20: ...ive DIN EN 61326 2004 05 EN 61326 1997 EN 61326 A1 1998 EN 61326 A2 2001 EN 61326 A2 2003 The designated product is in conformity with the European Low Voltage Directive 2006 95 EEC including amendmen...

Page 21: ...6 1997 EN 61326 A1 1998 EN 61326 A2 2001 EN 61326 A2 2003 The designated product is in conformity with the European Low Voltage Directive 2006 95 EEC including amendments Council Directive on the appr...

Page 22: ...regulations of the directive 93 42 EEC Directive of the council to adapt legal regulations of the member states on the subject of medical products dd 14 06 1993 Abl EG Nr L 169 S 1 12 07 1993 includin...

Page 23: ...al Law It should not be disposed off as part of domestic refuse For disposal please contact your dealer or the manufacturer Products which are infected infectious or contaminated with health endangeri...

Page 24: ...5 M main switch 11 maintenance 18 material quality 4 7 medical product 4 monitor relay 14 N normal operation 12 O operating mode indication 11 operating mode selection 12 operating time 13 operation...

Page 25: ...BASIC page 25 Notes...

Page 26: ...BASIC page 26 Notes...

Page 27: ...BASIC page 27...

Page 28: ...Memmert GmbH Co KG Postfach 1720 D 91107 Schwabach Tel 49 0 9122 925 0 Fax 49 0 9122 145 85 E Mail service memmert com www memmert com 12 08 2009 BASIC english D09803...

Reviews: