background image

V E N T I L A T I O N   &   H E A T   R E C O V E R Y

INSTALLATION INSTRUCTIONS AND 

USER GUIDE

Part no. 744011EN, Week 47/2019 EN

External wireless humidity sensor  

M-WRG-II FSF

1

2

3

Fig. 1:  External wireless humidity sensor

Item in Fig. 1

Description

1

Control button (touch-sensitive)

2

Status LED

3

Mode LEDs (5x)

Introduction

1.1  Notes on these instructions

These instructions contain important information that 

should be followed when installing and using the wire-

less humidity sensor.

 

Read all the instructions carefully to avoid possible risks and 

mistakes.

 

These instructions are part of the product. Keep the instructions 

in a safe place for future reference.

NOTICE

 

When operating the ventilation unit, also follow the operating 

instructions that were supplied with your unit.

1.2  Description

The wireless humidity sensor is used for wireless operation of 

ventilation units from the M-WRG-II and M-WRG series constructed 

from 2020 onwards (excluding bus unit types). It can also be used 

to determine the humidity level at an installation location selected 

by you, provided that it is within the wireless range. The “Humidity 

control” and “Automatic mode” ventilation programs use the 

transmitted values to automatically adjust the unit’s air flow to the 

required ventilation level. One wireless humidity sensor may be 

linked to each ventilation unit. If the ventilation unit has an internal 

humidity sensor, it will be automatically disabled. The wireless 

humidity sensor incorporates the humidity control function into 

ventilation units without an internal humidity sensor. The control 

button (item 1 in Fig. 1) is used to activate five different ventilation 

levels/programs. The current selection is indicated by one of the 

five green mode LEDs (item 3 in Fig. 1). The multi-coloured status 

LED (item 2 in Fig. 1) signals the wireless sensor and ventilation 

unit operating statuses. If the relative room air humidity exceeds 

60 % RH (factory setting) in the “Humidity control” or “Automatic 

mode” ventilation program, the ventilation level is increased contin-

uously up to max. 60 m

3

/h until the humidity in the room drops back 

below 60 % RH.

The wireless sensor is fixed to the wall with the dowels and screws 

provided (see section 4.1).

The optional M-WRG-FBH wireless remote control, part no. 5478-10, 

can be used to program the functions of the wireless sensor. You 

will find more details in the “User guide for wireless remote control 

M-WRG-FBH”. The wireless humidity sensor can also be used in 

parallel with the M-WRG-FBH wireless remote control, M-WRG-FT 

4-way wireless pushbutton switch and M-WRG-II FSC wireless CO

2

 

sensor and in conjunction with the U

2

 installation version and all 

M-WRG-II and M-WRG covers.

1.3  Target group

These instructions are intended for users of the wireless humidity 

sensor. No special prior knowledge is needed.

1.4  EU declaration of conformity

The wireless humidity sensor described below

  Type: M-WRG-II FSF 

  Part number: 733010

manufactured by

  Meltem Wärmerückgewinnung GmbH & Co. KG 

  Am Hartholz 4 

 

82239 Alling

conforms to the regulations and standards listed in the EU Declara

-

tion of Conformity.

1.5  Technical data

Product characteristics

Dimensions (W x H x D)

100 mm x 100 mm x 25 mm

Weight

approx. 125 g

Colour

white, similar to RAL 9010

Material of the plastic parts

ABS

Ambient conditions

Ambient temperature during  

operation

0 °C to 40 °C

Ambient temperature for storage and 

shipping

-20 °C to 40 °C

Relative humidity

0 % to 90 %,  

non-condensing

IP code (IEC 60529)

IP30

Battery

Size

AA, Mignon

Lifetime

approx. 2 years

Wireless connection

Communication frequency

868.3 MHz

Output power

at least 0 dBm

Data logging

Measurement range

0 % to 100 % RH

Measurement accuracy  

at 11 % to 89 % RH

 

3 % RH

Measurement resolution

1 % RH

Measurement stability over 5 years

1.5 % RH

1.6  Environmentally-friendly disposal

The components of the wireless humidity sensor must not be 

disposed of in the residual waste bin.

 

In Germany, metal and plastic components should be disposed 

of at the local recycling centre. The national regulations in other 

EU states should also be followed.

 

In Germany, electrical components should be disposed of in 

accordance with the Electrical and Electronic Equipment Act 

(ElektroG). In other EU states, the national implementation of the 

Waste Electrical and Electronic Equipment Directive 2012/19/EU 

(WEEE) should be followed.

 

In Germany, rechargeable batteries and accumulators should 

be disposed of in accordance with the Batteries Act (BattG). The 

national implementation of the Battery Directive 2006/66/EC 

should be followed in other EU states.

 

The regulations and statutory requirements in your own country 

concerning disposal should also be followed.

1.7  Explanation of the symbols used

 

This symbol indicates an action to be taken.

 

— This symbol indicates a list. 

Safety

The wireless humidity sensor is approved only for use in dry interior 

areas and must be protected against humidity and moisture to 

prevent short-circuits.

2.1  Notes on operation

This unit may be used by children from 8 years old and by persons 

of restricted physical, sensory or mental abilities or persons lacking 