Use of the helmet lamp TL257 - Ex 

The helmet lamp TL257 Ex is fitted with five most luminous LED’s 
and offers a clearly focused and steady projected image due to an 
optical  light  concentration.  This  helmet  lamp is  an  ideal  essential 
complement  of your  equipment  in  the  area with  explosion  risk  in 
the sectors 1, 2 and 21, 22 through its harmonised light spreading 
and the individually adjustable luminous angle. 
The  3  switching  cycles  enable  an  operation  of  2  LED’s  for  the 
local  range,  3  LED’s  for  the  remote  range  or  all  5  LED’s  at  the 
same time. Fastening of the lamp directly on the helmet ensures a 
uniform and  centred  weight  arrangement  and position  -  the  lamp 
therefore always flashes in the line of sight. 
The  lamp  can  be  purchased  with  different  accessories,  like  a 
helmet holder or a reflecting band. 
Mounting and removing of the lamp on the helmet is truly simple 
and to be done with a few turns with no need of any tool. 

 

Technical Data 

Lighting distance: 

          50 m 

Lighting time: 

                         24 h  

Batteries: 

                         3 x AA 1,5 V 

Weight: 

                         280 g without batteries 

Lighing appliances:                     5 x LED white 
Light intensity:                           5 x 18000 mcd 
Life-time: 

                         > 20000 h (LED) 

Ambient temperature range:      - 20°C up to + 40°C 
Housing: 

                         IP54 

Type-tested Batteries 

 

 

 

 

 

Maintenance and care of the lamp 

Please clean the lamp only with a moist cloth – Danger can occur 
through static charging. The sealing rings have to be checked and 
lubricated  with  silicone  grease  after  each  battery  replacement. 
Deposits,  like  e.g.  dirt,  salt,  sand  or  other  impurities  are  to  be 
removed  carefully. We  recommend  a  regular  cleaning  of the  len-
ses  of  the  lamp  to  ensure  a  constant  lighting  quality.  In  case  of 
damage  of  the  sealing  rings  or  other  parts,  the  article  can 

NO 

LONGER

  be  used  in  ex-areas.  The  batteries  should  not  be  ex-

posed  to  direct  sunlight  or  be  dried  above  a  fire.  Do  not  store 
batteries over 60°C (146°F).  

 

Malfunctions 

As  soon  as  the  reliability  of  the  lamp  is  not provided  anymore,  it 
must be switched off and removed immediately from the risk area. 
The non intended reconnection must be secured. We recommend 
to send the lamp in this case to the manufacturer for overhauling  
 
Cases in which the lamp is not to be used any more: 

 

Transport damages 

 

Visible damages at the housing 

 

Improper strain of the lamp 

 

Unreadable labelling of the lamp 

 

Exceeding of allowed critical values 

 

Improper storage of the lamp 

 

Occurance of failures 

For any further queries, please contact our Customer Service. 

Guarantee and Liability 

This article has a guarantee of 2 years for manufacture and mate-
rial, except the batteries. This guarantee does not apply to articles 
which have been improperly used, modified, neglected (incl. usual 
wear), damaged through accidents or exposed to abnormal oper-
ating conditions as well as to a faulty handling. 
We  assume  no  liability  whatsoever  for  direct,  indirect  conse-
quences caused by accident. This also applies for any other type 
of  damage  as  a  result  of  the  use  of  this  lamp.  We  will  likewise 
assume  no  liability  at  all  for  damage  to  property  or  to  persons 
caused by faulty handling or non-observance of the safety instruc-
tions.  In  case  damages  are  detected  on  the  lamp,  please  DO 
NOT USE IT anymore !  

Be aware of life threatening danger!

 

 

Safety instructions 

The  use  of  the  lamp  calls  for  the  observance  of  the usual  safety 
instructions by the user in order to eliminate any operating error of 
the lamp. 

If  the  luminous  power  of  the  lamp  is  not  satisfying 
any more, the batteries have to be replaced. 
Following safety instructions are to be followed when 
changing the batteries: 

 

The  battery  cover  should only be opened in a non-hazardous 
environment!

 

 

We recommend to replace all 3 batteries at once. 

 

Never fit in mixed new and used batteries. 

 

Only batteries of the accordingly allowed type can be fitted in 
(see table under Technical Data). 

 

Only use batteries of same type and same manufacturer. 

 

Please observe the polarity of the batteries. 

 

Carrying along of additional batteries in ex-areas is not permit-
ted. 

The danger zone marking is noted down at the lamp housing. The 
article is 

NOT

 adapted for a permanent use in danger zone 0 and 

20!  
 

Mellert SLT GmbH & Co.KG 
Declaration of Conformity, EU-Guideline 94/9/EG 

 

We, Company Mellert SLT GmbH & Co.KG, Langenmorgen 2, 75015 Bretten, 
declare under our exclusive liability for the delivery of the product 
 
Model Type: 

TL257 Ex 

Standard: 

EN 60079-0:2004 ; EN 60079-11:2007 ; EN 61241-0:2006                                  

.                               EN 61241-11:2006  
 
object  of  this  declaration  that  it  complies  with  the  basic  health  and  safety  re-
quirements of the ATEX-Guideline 94/9/EG, provided that the model mentioned 
above is used, maintained and serviced according to the attendant instructions. 

 

Inspection Authority for EC – Type approval:  

IBEXU 

Mellert SLT GmbH & Co KG                 

 

 Bretten, 2

nd

  Mai 2007              (R. Gelmroth, Director) 

Code:  

 

II 2G  Ex ia IIC T4  

or 

 

 

II 2D   Ex ia D21 T 135 °C

 

       

       

       

Manufacturer 

Type 

Energizer  E92 

AA, LR 06     
1,5 V 

VARTA/ High Energy 4906 

AA, LR 06     
1,5 V 

85.590.-951.00 