Mellanox Technologies
45
4.2.1.4 UID LED
The UID LED is a debug feature, that the user can use to find a particular system within a cluster
by turning on the UID blue LED. This is a future feature that is not yet available.
4.2.1.5 Bad Port LED
The Bad Port LED indicator is used to indicate symbol errors in one or more system ports.
Table 19 shows the bad port status LED assignment.
Table 19 - Bad Port LED Assignments
LED Configuration
Description
Action Required
Off
No symbol errors have been received in last
few seconds (normal condition)
N/A
Flashing Amber
Error, one or more ports have received symbol
errors.
Possible causes are:
• Bad cable
• Bad connection
• Bad connector
Check symbol error counters on the sys-
tem UI to identify the ports.
Replace the cable on these ports.
Flashing Amber
Power supply warning events where the power
supply continues to operate; high temp, high
power, high current, slow fan.
Call your Mellanox representative for
assistance.
Off
No AC power to all power supplies
Call your Mellanox representative for
assistance.
Table 18 - Power Supply Unit Status Rear LED Assignments
LED Behavior
Description
Action Required
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...