background image

 

Dismantling Guide

 

Rev. 1.0 

 

 

 

 

 

Mellanox Technologies Confidential

 

 

 

2 of 13

 

 

 

NOTE: 

THIS INFORMATION IS PROVIDED BY MELLANOX FOR INFORMATIONAL PURPOSES ONLY 
AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE 
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 
ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE FOR ANY DIRECT, 
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES 
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; 
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND 
ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF 
THIS HARDWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 

 

 

 

Mellanox Technologies, Inc. 

350 Oakmead Parkway Suite 100 

Sunnyvale, CA 94085 

 

U.S.A. 

www.mellanox.com

  

Tel: (408) 970-3400 

Fax: (408) 970-3403 

Mellanox Technologies Ltd 

PO Box 586 Hermon Building 

Yokneam 20692 

Israel 

Tel: +972-4-909-7200 

Fax: +972-4-959-3245 

 

 

 © Copyright 2011. Mellanox Technologies, Inc. All Rights Reserved. 

Mellanox®, BridgeX®, ConnectX®, InfiniBlast®, InfiniBridge®, InfiniHost®, InfiniRISC®, 
InfiniScale®, InfiniPCI®, PhyX® and Virtual Protocol Interconnect® are registered trademarks of 
Mellanox Technologies, Ltd. CORE-Direct and FabricIT are trademarks of Mellanox Technologies, Ltd.  

All other marks and names mentioned herein may be trademarks of their respective companies.

Contact Information

 

 
Should you have any questions regarding our Products, please feel free to contact us directly or contact our 
local distributors. 
 

Mellanox Technologies Call Center  

Tel: + 
Email: 

[email protected]

 

Summary of Contents for MIS5022Q-1BFR

Page 1: ...Document no 3408 Mellanox Technologies Confidential http www mellanox com Dismantling Guide OPNs MIS5022Q 1BFR MIS5022Q 1BRR Rev 1 0...

Page 2: ...E EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Mellanox Technologies Inc 350 Oakmead Parkway Suite 100 Sunnyvale CA 94085 U S A www mellanox com Tel 408 970 3400 Fax 408 970 3403 Mellanox Technol...

Page 3: ...er Supply Unit 8 1 5 Extracting the Fan Unit 10 1 6 Extracting the Board 12 List of Tables Table 1 Revision History 4 Table 2 Switch OPNs for this Procedure 4 Table of Figures Figure 1 Remove the Cove...

Page 4: ...g the requirements of WEEE recycling Intended Audience This manual is intended for technicians who dismantle the switch systems as a reference for WEEE recyclers Mellanox Technologies emphasizes the i...

Page 5: ...the requirements of the European Union s WEEE waste electrical and electronic equipment directive The directive mandates how the materials used in electrical and electronic equipment must be disposed...

Page 6: ...RoHS 6 The last digit of the product part number represents the RoHS type For example MIS5022Q 1BRR the last R RoHS 6 InfiniBand switch system systems are comprised of Cover Power Supply Unit PSU Har...

Page 7: ...Guide Rev 1 0 Mellanox Technologies Confidential 7 of 13 1 3 Cover 1 Unscrew the rear side screws and slide the cover to the back for opening it 2 Slide the top to the rear and lift off Figure 1 Remov...

Page 8: ...e power Supply unit is located on the side of the switch unit next to the main board Figure 2 PSU Location 1 Disconnect the 3 harness connectors from the main board the inlet and the ground Figure 3 H...

Page 9: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 9 of 13 Figure 4 Remove the Power Supply Unit from the Switch...

Page 10: ...anox Technologies Confidential 10 of 13 1 5 Extracting the Fan Unit The Fan unit is located in the rear of the system Figure 5 Fan Location 1 Disconnect the 3 harnesses from the fan unit to the board...

Page 11: ...nfidential 11 of 13 2 Disassemble the 2 screws attaching the Fan wall to the bottom of the mechanical enclosure base 3 Disassemble the 4 screws attaching the Fan wall to the rear of the mechanical bas...

Page 12: ...Rev 1 0 Mellanox Technologies Confidential 12 of 13 1 6 Extracting the Board 1 Disassemble the 5 screws and washers attaching the main board to the mechanical base Figure 8 Board Screw Locations 2 Rem...

Page 13: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 13 of 13 3 Unscrew the Heat sink screws to remove the Heat sink Figure 9 Remove Heat Sink...

Reviews: