Appendix C: QSFP Interface

GND

Rx2n

GND

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

Rx1n

Rx2p

Rx1p

GND

GND

GND

GND

GND

GND

Tx2n

Tx1n

Tx2p

Tx1p

Tx4n

Tx3n

Tx4p

Tx3p

GND

GND

Rx4n

Rx3n

Rx4p

Rx3p

GND

GND

SDA

SCL

Vcc Rx

ResetL

ModSelL

LPMode

Vcc1

VccTx

IntL

ModPrsL

Table 10 - InfiniBand QSFP Connector Pinout  

Connector 

Pin Number

Connector 

Pin Name

Signal Description

1

GND

Ground

2

Tx2n

Transmitter Inverted Data Input 

3

Tx2p

Transmitter Non-Inverted Data Input 

4

GND

Ground

5

Tx4n

Transmitter Inverted Data Input 

6

Tx4p

Transmitter Non-Inverted Data Input 

7

GND

Ground

8

ModSelL

Module Select 

9

ResetL

Module Reset

10

Vcc Rx

+3.3 V Power supply receiver 

11

SCL

2-wire serial interface clock 

12

SDA

2-wire serial interface data 

13

GND

Ground

14

Rx3p

Receiver Non-Inverted Data Output 

15

Rx3n

Receiver Inverted Data Output 

16

GND

Ground

17

Rx1p

Receiver Non-Inverted Data Output 

18

Rx1n

Receiver Inverted Data Output 

19

GND

Ground

20

GND

Ground

21

Rx2n

Receiver Inverted Data Output 3

22

Rx2p

Receiver Non-Inverted Data Output 3

23

GND

Ground

24

Rx4n

Receiver Inverted Data Output 3

25

Rx4p

Receiver Non-Inverted Data Output 3

26

GND

Ground

27

ModPrsL

Module Present 

28

IntL

Interrupt 

29

Vcc Tx

+3.3 V Power supply transmitter 

30

Vcc 1

+3.3 V Power Supply 

31

LPMode

 Low Power Mode 

32

GND

Ground

33

Tx3p

Transmitter Non-Inverted Data Input 

34

Tx3n

Transmitter Inverted Data Input 

35

GND

Ground

36

Tx1p

Transmitter Non-Inverted Data Input 

37

Tx1n

Transmitter Inverted Data Input 

38

GND

Ground

Summary of Contents for InfiniScale MTS3600Q-1BNC

Page 1: ...lanox Technologies InfiniScale IV 36 Port QSFP InfiniBand Switch User Manual P N MTS3600Q 1BNC MTS3600Q 2BNC MTS3600Q 1UNC MTS3600Q 2UNC MTS3600R 1BNC MTS3600R 2BNC MTS3600R 1UNC MTS3600R 2UNC Rev 2 0...

Page 2: ...SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TEST ING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS THE CUS TOMER S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MEL...

Page 3: ...erting the Power Supply Unit 17 2 2 5 InfiniBand Cable Installation 18 2 2 6 Extracting and Inserting the Fan Unit 19 2 2 7 Replacing the Battery in the Management Module 20 2 3 Disassembly of the Swi...

Page 4: ...Fabric IT section April 2009 Rev 1 7 inserted procedure to replace the battery April 2009 Rev 1 6 Changes to installation kit and procedure January 2009 Rev 1 5 added installation instructions added E...

Page 5: ...Update Tools See http www mellanox com Downloads Firmware Tools Note that the Switch System described in this manual is based on Mellanox Technologies InfiniScale IV switch device Mellanox OFED Stack...

Page 6: ...port Unmanaged QSFP 40Gb s InfiniBand switch with two power supplies MTS3600R 1UNC 36 port Unmanaged QSFP 20Gb s InfiniBand switch with one power supply MTS3600R 2UNC 36 port Unmanaged QSFP 20Gb s Inf...

Page 7: ...iBand fabric This switch requires an InfiniBand compliant Subnet Manager running from one of the hosts All that is required for normal operation is to follow the usual precautions for installation and...

Page 8: ...t to the left of the primary power supply unit and labeled Sys The system status indicators should be as follows When the switch is plugged in within a few seconds the STATUS LED should light up green...

Page 9: ...nit installed a second Power Supply Unit can be added to increase security hot swap ability and to add redundancy Figure 5 MTS3600 QSFP Front Panel LED Configuration Status OK The system is up and run...

Page 10: ...ollowing fan status conditions are possible Table 6 Fan Status LED Configurations 2 1 2 I2 C Connector The MTS3600 supports an I2C compatible interface on the front panel This interface is used to pro...

Page 11: ...ement operation 2 2 Switch Platform Installation and Operation Installation and initialization of the switch platform are straightforward processes requiring attention to the normal mechanical power a...

Page 12: ...nce around the ventilation openings The chassis should not be stacked on any other equipment If the chassis falls it can cause bodily injury and equipment damage This product includes a blank cover ov...

Page 13: ...should use a rack capable of supporting the mechanical and environmental characteristics of a fully populated platform 2 2 2 1 Installing the Switch in the Rack Tools needed Phillips Screwdriver ESD S...

Page 14: ...ace the ESD mat on the floor where you will be working and put on the ESD strap Make sure the ESD strap is touching your skin and that the other end is connected to a verified ground 2 Choose which si...

Page 15: ...itch that you want to be even with the vertical support of the 19 rack Use four of the flat head screws for each rail slide There are two sets of holes in the rail slide Select the set of holes to eit...

Page 16: ...within reach 7 Slide the switch into the rails 8 Put the switch into place and screw the bolts into the nuts from step 4 Tighten the bolts to 9 2 Nm or 81 5 pound inches 9 Tighten all of the screws 10...

Page 17: ...y modules for proper insertion before plugging in a power cable Caution After inserting a power cable and confirming the green system status LED light is on make sure that the Fan Status indicator sho...

Page 18: ...the power cord into the supply connector Note The green PSU indicator should light and the yellow indicator should remain off If not extract the PSU and re insert it 2 2 5 InfiniBand Cable Installatio...

Page 19: ...re bending upward or downward in the rack Figure 13 Cable connections to the Switch 2 2 6 Extracting and Inserting the Fan Unit This switch can operate indefinitely with one of the three fans in the f...

Page 20: ...m the rack 3 Put on an ESD strap and ground the strap to a valid ground 4 Remove the rail slides from the switch Put aside the rail slides and screws for later use 5 Remove the cover from the switch a...

Page 21: ...he eight caged nuts 2 4 Disposal According to the WEEE Directive 2002 96 EC all waste electrical and elec tronic equipment EEE should be collected separately and not disposed of with regular household...

Page 22: ...odule The management module for this switch system runs SW that can manage the chassis An option to upgrade the management module to be able to manage the whole fabric is available See your Mellanox r...

Page 23: ...r an RJ45 connector on the host PC side 3 2 2 2 Accessing the CPU via Keyboard Video Mouse KVM 1 Connect a keyboard to the one of the USB ports a video device to the video connector and a mouse to the...

Page 24: ...re robust and can manage a whole fabric 4 1 FabricIT FabricIT EFM is a software based management system that can be run with either a command line interface or with a GUI interface The GUI interface c...

Page 25: ...n the PSU Unit is on 3 Remove and reinstall the power cable Check that the power outlet in the wall is working 4 Remove and reinstall the PSU Make sure the mating connector of the new unit is free of...

Page 26: ...ure that the latest FW version is installed on both the HCA and the switch 4 If media adapters are used check that the all connections are good tight and secure The activity LED does not come on Check...

Page 27: ...ion of 40Gb s 20Gb s 10Gb s 8 InfiniBand Virtual Lanes for all ports Baseboard Performance and Device man agement Agents for full InfiniBand In Band Management QDR Safety EMC Emissions Environmental A...

Page 28: ...tual Lanes for all ports Baseboard Performance and Device man agement Agents for full InfiniBand In Band Management DDR Safety EMC Emissions Environmental Acoustic Sound power level US Canada cTUVus E...

Page 29: ...digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment T...

Page 30: ...Japan Class A Statement 0 0 1 Translation This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment...

Page 31: ...Scale IV 36 Port QSFP InfiniBand Switch User Manual MellanoxTechnologies Rev 2 0 0 31 Appendix B Switch Hardware Components Fan Unit Primary Power Supply Unit Place for Optional Secondary Power Supply...

Page 32: ...etL Module Reset 10 Vcc Rx 3 3 V Power supply receiver 11 SCL 2 wire serial interface clock 12 SDA 2 wire serial interface data 13 GND Ground 14 Rx3p Receiver Non Inverted Data Output 15 Rx3n Receiver...

Page 33: ...Unit for QSFP MTF000960 Management module 405 PPC SA000102 Management module upgrade to 460 PPC SA000102 RS232 CABLE DB9 TO DB9 HARNESS HAR000040 Power cord Type B for USA Canada Mexico Taiwan ACC000...

Page 34: ...ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens Ce produit comporte un couvercle transparent sur l esp...

Page 35: ...10 Codes lectriques locaux et nationaux Ce mat riel ne doit tre install remplac ou entretenu que par du personnel form et qualifi L limination de ce mat riel doit s effectuer dans le respect de toutes...

Page 36: ...Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herunt erf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren Dieses Produkt verf gt ber eine Abdeckung ber dem...

Page 37: ...nale elektrische Bestimmungen Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden Die Entsorgung dieses Ger ts sollte unter Beachtung aller...

Page 38: ...n Denmark The AC cord shall have an integral ground wire and can only be plugged into a fully grounded outlet Finland Norway Sweden Do not connect this unit to any outlet that is not fully grounded La...

Reviews: