ConnectX-2 Card User Manual
Rev 1.0
Mellanox Technologies
23
3. Install the adapter drivers.
4. Update the adapter firmware if needed.
The configuration of the card is dependant upon your choice to use InfiniBand or Ethernet.
4.3.1 Identify the Card in Your System
4.3.1.1 Windows
1. Open Device Manager. Click start--> Run, and then enter “devmgmt.msc”.
2. Check the Device Manager under “Other devices” for “PCI Device” (Windows 2003) or
“InfiniBand Controller” (Windows 2008/R2).
Figure 7: Hardware Devices
3. Select a PCI Device / InfiniBand Controller entry.
If you cannot find any PCI device, click Action --> Scan for hardware changes. If no
PCI devices are detected, check that the network adapter card(s) is correctly installed in
the PCI slot or try installing the adapter card into a different PCI slot.