MLX90130
13.56MHz RFID Transceiver
3901090130
Page 19 of 37
Jan-2014
Rev. 004
6.6.1 Support of extended frames
In reader mode it is possible to receive up to 528 bytes of frame data. The extended size is included in the
command code as follows:
Figure 10: Coding of Length of extended frames
Consequently, the
ResultCode
returned depends on the length of the decoded frame received by the
MLX90130.
Direction
Result Code
Length (LEN)
Effective length of received data
Comment
MCU - device
0x80
0x00 – 0xFF
0 – 255 bytes
0xA0
256 – 511 bytes
0xC0
512 – 528 bytes
0x90
0 – 255 bytes
In ISO/IEC14443A only in case of
none integer number of bytes
0xB0
256 – 511 bytes
0xD0
512 – 528 bytes
Table 14: Coding of Length of extended frames
1 L L 0 0 0 0 0
ResultCode
L L L L L L L L
Len
0
0
7
7
x x x x x x x x
Data byte 0
0
7
L L L L L L L L
Number N of data bytes
0
7
L L
9
8