INSTALLATION
3-5
MA-5168-ENG
ADHESIVE MELTER CANTHO
Connecting the panel’s power supply
The Cantho melters are supplied to be connected to the 230 VAC single phase
power supply with neutral.
Open the door of the electric cabinet. Pass the power cable (max. Ø12 mm)
through the Pg 13.5 bushing and fix it, ensuring that the cable is perfectly
secured.
Connect each of the power cable’s wires in their corresponding position in the
input terminals (see drawing).
Warning:
Risk of electrical shock. Carelessness may cause injury or death.
Open the electric cabinet door. Thread the power cord (Ø6-12 mm) through the
electrical wall bushing Pg 13.5 and fasten it to the inside anchor, making sure
that the cord remains well fixed and allows the plate to be mounted again.
Connect each wire of the power cable in its corresponding place of the input
terminals (see drawing).
The unit’s maximum consumption value can be found on the nameplate.
Pneumatic connection
Before connecting the pneumatic supply of the pneumatic cylinder and the
discharge valve, ensure that the pressure regulator is completely closed
(pressure ‘0’). To do so, turn the regulator control anti-clockwise; the control
is located on the upper lid, next to the cylinder.
Connect the plant’s air supply (6 bar max.) to the equipment input using a
flexible tube with an outer diameter of 6 mm. The unit has a quick release
coupling for this purpose.
Allow the air to flow and turn the pressure regulator clockwise until you reach
the required pressure.
On the pressure gauge, you can see the pressure applied to the cylinder on its
scale in ‘bar’.
L
11
N
22
PE
33
2X4
2X4
Ø6 mm
Ø6 mm
Summary of Contents for Cantho
Page 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Page 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Page 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Page 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Page 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Page 64: ......