GD-5510-01
Instructions Manual
(6) Step angle switch input(C.S)
① Operating current range : 2.6mA~19.5mA
The photo-coupler turns on with
inter-terminal voltage of 4.5 V~26.4 V.
(Photo-coupler diode V
F
≒ 1.1 V)
● Step angle division is switched to 1/20 divisions with the photo-coupler ON.
The setting for the STEP ANGLE SELECT switch is ignored.
● No displacement occurs even if the step angle is switched by the C.S signal.
② Timing chart
Number of divisions
1/20divisions
Number of divisions
of STEP SEL switch
of STEP SEL switch
ON
OFF
C.S
t1≧30ms
t2≧ 1ms
● Switching the step angle by the C.S signal requires time t1 and t2 before
and after inputting drive pulse.
③ STEP ANGLE SELECT switch and C.S signal
〔STEP ANGLE SELECT switch〕
〔When the C.S signal is input〕
1/20 divisions
(0.036°)
5
6
7
1/200
1
2
1/2
1/4
8
0.0009
1/400
1/800
1/10
0.072
9
1/20
1/40
1/100
0.0018
0.18
0.0036
0.018
0.0072
0.036
t2
0
1/1
Step angle(°)
0.72°motor
0.72
Number of
Divisions
Switch No.
CWP
CCWP
t1
t2
t1
3
4
0.36
11
12
C.S+
C.S-
GD-5510-01
(J1)
Photo-coupler
1.3kΩ