![background image](http://html1.mh-extra.com/html/melec/adb-5f30a/adb-5f30a_instruction-manual_1767044014.webp)
Instructions Manual
4.Setting
4-1.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from six different
types of step angles.
The switches are factory-set to [20 divisions].
(1) Set the step angle required by the STEP SEL switch [SA,SB,SC].
●Relationship between the STEP SEL switch and the step angle.
(Factory setting)
●Step angles are theoretical values.
0.72
0.36
1/1
1/2
ON
OFF
ON
1/4
OFF
ON
0.18
0.072
0.036
1/10
1/20
SB
1/
Divisions
Step angle(°)
0.72°motor
STEP SEL switch
SC
SA
ON
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
0.018
OFF
ON
OFF
1/40
CAUTION
-14-