-phase Stepping Motor Driver

ADB-5F30v1
ADB-5F30A

Instructions Manual

(For designers' use)

MN0107-

2

Please ensure to read and understand this
Instructions Manual before using the product.
Please keep this Instructions Manual at hand
so that it is always available for reference.

Summary of Contents for ADB-5F30A

Page 1: ...30v1 ADB 5F30A Instructions Manual For designers use MN0107 2 Please ensure to read and understand this Instructions Manual before using the product Please keep this Instructions Manual at hand so that it is always available for reference ...

Page 2: ...river ADB 5F30 V1 with emphasis on the specifications assuming that our readers are engaged in designing of control devices incorporating stepping motors Please ensure to read and understand this Instructions Manual before using the product Please keep this Instructions Manual at hand so that it is always available for reference 2 ...

Page 3: ...mstances in advance Consequently this instructions manual describes all the hazardous and dangerous circumstances and situations which can be foreseen and anticipated as well as necessary precautions All the above descriptions are being titled by the following symbol marks and signal words namely Represents warnings ignorance of which can cause accidents involving fatal or serious physical injurie...

Page 4: ...ions 7 Safety Information for Handling 10 Characteristics 10 Product Configuration 10 Appearance Signal I O Connector J1 DC Input Motor Output Connector J2 J3 POWER LED Operating Section Setting STEP ANGLE SELECT switch Setting HOLD CURRENT ADJUSTMENT trimmer 11 12 12 13 14 15 O H A LED 12 1 1 1 2 2 1 2 2 2 3 3 1 3 3 3 2 3 4 3 5 4 1 4 2 Conditions for Installation Mounting Method Overview of Conne...

Page 5: ...ntenance and Check up Troubleshooting Storing Disposal 26 27 28 28 8 1 8 2 9 1 9 2 I O Signal General Specifications Drive pulse input Example Circuit Connection Motor excitation stop input Phase signal output Dimensions Applicable Motors Torque Characteristics CW CCW M F P O 29 33 35 36 37 31 32 30 10 2 10 1 10 4 10 5 10 6 4 3 2 1 42 10 7 Conforming to Europe standards 5 ...

Page 6: ...ause injury 5 Do not transport move install the product perform connections or inspections when the power is on Doing so may cause electric shock injury or fire 6 Only qualified personnel are allowed to transport move install the product perform connections or inspections Failure to do so may cause injury or fire 7 Do not touch the driver during operation or immediately after stopping Doing so may...

Page 7: ...ge of the machine or injury due to unexpected rotation of the motor Ensure correct setting When setting up the HOLD CURRENT ADJUSTMENT trimmer A high setting value may cause burn on the skin due to overheating of the motor Do not select a high value beyond the required When setting up the DRIVE CURRENT SELECT switch A high setting value may cause burn on the skin due to overheating of the motor Do...

Page 8: ...tor Output Connectors J2 J3 Erroneous connection may cause breakage of the motor or the driver Correctly connect the DC Input Motor output connector When inputting power Breakage of the machine or injury is apprehended due to unexpected behavior of the motor Maintain the state where emergency stop is enabled at any time When inputting the motor excitation stop M F signal Deterioration of the holdi...

Page 9: ... LED comes on Overheating may cause fire Stop operation when this LED comes on When performing maintenance and checking Injury or fire is apprehended due to unexpected behavior Do not replace fuse Do not disassemble repair or modify WARNING WARNING 9 ...

Page 10: ...e set up 1 Model Name Exterior Dimensions mm ADB 5F30v1 H 65 W 57 D 29 ADB 5F30A H 65 W 57 D 32 Applicable motors and setting for each motor are given in the table 10 5 Applicable Motors 2 2 Product Configuration The product consists of the main frame and the accessories ADB 5F30V1 One unit Housing for J1 51103 0800 Molex One unit accessory Housing for J2 51103 0200 Molex One unit accessory Housin...

Page 11: ... to operate CCW CCW M F Shuts off output current to drive the motor M F P O Outputs the signal when the motor excitation state is the excitation home position R GND 4 3 2 1 8 7 6 5 CW drive pulse signal input terminal CCW drive pulse signal input terminal Motor excitation stop signal input terminal Phase signal output terminal GND terminal for P O signal 11 ...

Page 12: ... DC power supply is connected 3 3 POWER LED POWER LED GREEN comes on upon inputting power 3 4 O H A LED O H A LED RED comes on when internal temperature of the driver has reached approx 70 or more 0V DC 2 J2 5 DC 24V DC 1 RED ORN GRN BRN BLU GRY BLK ORN 3 4 BLK 1 VIO BLU GRN 2 YLW WHT RED DC input terminal Motor output terminal 12 ...

Page 13: ... 1 STEP ANGLE SELECT switch DRIVE CURRENT SELECT switch PULSE INPUT TYPE SELECT switch 1 2 OFF OFF OFF DH1 Use it with OFF DRIVE HOLD CURRENT automatic switching time is selected Selects a pulse input type Name of Operating Section Sub adjustment switch Sub adjustment switch HOLD SWITCHING TIME SELECT switch Name of Operating Section Function Selects a step angle Selects DRIVE CURRENT STEP ANGLE S...

Page 14: ...e selected from six different types of step angles The switches are factory set to 20 divisions 1 Set the step angle required by the STEP SEL switch SA SB SC Relationship between the STEP SEL switch and the step angle Factory setting Step angles are theoretical values 0 72 0 36 1 1 1 2 ON OFF ON 1 4 OFF ON 0 18 0 072 0 036 1 10 1 20 SB 1 Divisions Step angle 0 72 motor STEP SEL switch SC SA ON ON ...

Page 15: ... to the required value Relationship between the trimmer scales and HOLD CURRENT HOLD CURRENT DRIVE CURRENT Ratio of HOLD CURRENT typical Trimmer Scale of the trimmer HOLD CURRENT changes relative to DRIVE CURRENT setting The ratio of HOLD CURRENT of 100 represents the same as the setting for DRIVE CURRENT The greater the ratio of HOLD CURRENT grows the more heat the motor generates when is on hold...

Page 16: ...se burn on the skin due to overheating of the motor Do not select a high value beyond the required DRIVE CURRENT is set up with the DRIVE I SEL switch The switch is factory set to IH 1 Set the DRIVE I SEL switch IH IL to the setting specified in the table 10 5 Applicable Motors CAUTION 16 ...

Page 17: ... CW and CCW set the SPI SEL switch to OFF 2P When the motor is operated with the pulse signal and direction signal input set the SPI SEL switch to ON 1P In the case that 1 pulse input method is selected the CCW terminal becomes direction signal input designating the direction of the motor rotation Drive pulse set to the CW terminal CW CW The input timing is same with 2 pulse input method and 1 pul...

Page 18: ...HOLD SWITCHING TIME SELECT switch DRIVE HOLD CURRENT automatic switching time is set up with the DHT SEL switch The switch is factory set to DH1 1 Set the DHT SEL DH1 DH2 switch OFF DH1 150ms DHT SEL Hold Switching Time ON DH2 15ms 18 ...

Page 19: ...exposed to splashes of water oil or chemicals 2 Install the driver at least 15mm away from other equipment 3 Considering heat release control the ambient temperature around the driver within the specified value Take measures against accumulation of heat such as allowing generous space around the driver or installing a fan so that heat release is taken care of Install the driver securely in contact...

Page 20: ...are used The following items are required 1 Fix the product at the two round holes on the main body Mounting example 2 M 3 screw 8mm or more in length 2 2 M 3 spring washer M 3 flat washer Fixing with a screw M 3 flat washer Fixing with a screw M 3 spring washer M 3 screw 20 ...

Page 21: ...CW input signal line Provide shielding for the signal line where considerable noise is generated Use the wire material of the characteristic that is difficult to burn Provide shielding for the motor line if it generates significant noise For the driver s power supply use a DC power supply with reinforced insulation on its primary and secondary sides Example configuration The metallic enclosure and...

Page 22: ...ousings to the connectors on the main frame The contacts for J1 are 8 pieces When inserting keep pushing J1 housing into the connectors until it is locked Also check if the contacts are not displaced from the housing In wiring isolate the J1 signal lines from equipment that may be a source of noise the power line and the motor line Surface on which the contacts are inserted Housing for J1 Crimping...

Page 23: ...sing Make sure that the housing No and the connector No on the main frame are matched before inserting the contacts 3 Connect the housings to the connectors on the main frame The contacts for J2 for DC input are 2 pieces and for J3 motor output are 5 pieces When inserting keep pushing J2 J3 housings into the connectors until it is locked Also check if the contacts are not displaced from the housin...

Page 24: ...olors of the leads of the motor Use a cable of 5m or less for the motor cable 6 4 Inputting Power Breakage of the machine or injury is apprehended due to unexpected behavior of the motor Maintain the state where emergency stop is enabled at any time 1 Input the DC power supply DC 24V in the cable that connected to No 1 and No 2 terminals of J2 VIO BLK 1 1 BLU 3 RED GRN 2 2 GRY Motor YLW WHT RED 4 ...

Page 25: ...or wiring are correctly performed Setting of HOLD SWITCHING TIME SELECT switch DHT SEL DH1 DH2 1P 2P Check SPI SEL Remarks Check Points Setting of PULSE INPUT TYPE SELECT switch Connection of J3 Connection of J2 Connection of J1 DC DC MOTOR Setting of HOLD CURRENT ADJUSTMENT trimmer Setting of DRIVE CURRENT SELECT switch Trimmer Scale Setting of STEP ANGLE SELECT switch STEP SEL IH IL SA SB SC DRI...

Page 26: ...ot disassemble repair or modify 1 As for maintenance inspections the engineer of the specialty shall do it 2 We recommend that the following check ups should be performed periodically Checking for any loosened contact on the connectors Checking for any flaw and crack on the cabling 3 In case of failure return the driver to us and have it repaired WARNING 26 ...

Page 27: ...the pulse signal signal line Voltage and wave form of the Pulse signal of wrong pulse signal specifications Setting of the DRIVE CURRENT Wrong Setting for DRIVE SELECT switch CURRENT selection Setting of the STEP ANGLE Wrong setting for the step SELECT switch angle Driver failure Motor failure 4 The motor steps out Starting pulse speed Starting pulse signal speed during acceleration is too high Ac...

Page 28: ...he range set out in the specifications Where there is no explosive corrosive or inflammable gas Where it can be protected from dust salt or iron powder Where the product main frame is not exposed to direct vibration or shock Where it is not exposed to splashes of water oil or chemicals 2 Do not allow standing or placing anything heavy on the product 9 2 Disposal 1 Dispose of the product as industr...

Page 29: ... Indoor Exposure to direct sun is not allowed 1 Input voltage range is DC 24V 10 2 Use a power supply that provides sufficient input current No freezing allowed Overheat alarm Supply Power Motor output current Input Signal Output Signal Functions of Operating Sections Overheat alarm LED O H A LED Operating Ambient Temperature 0 40 No condensation allowed Storing Temperature 10 55 No freezing allow...

Page 30: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 30 ...

Page 31: ...en at the rising edge t4 greatly varies according to the inertial moment including that of the motor Automatic switching for DRIVE HOLD DRIVE HOLD HOLD t1 t1 15ms HOLD SWITCHING TIME SELECT switch ON DH2 t1 150ms HOLD SWITCHING TIME SELECT switch OFF DH1 Inputting drive pulse causes the current output to the motor to change from HOLD CURRENT to DRIVE CURRENT which returns to HOLD CURRENT in about ...

Page 32: ...ent is shut off with the photo coupler ON At this time motor torque changes to detent torque When this signal is input motor torque may be lost resulting in failure to retain the load transported In particular this risk is high with the vertical drive such as the Z axis Timing chart M F t1 t2 t1 300ms t1 Time required for the motor to be enabled t2 5ms t2 Time required for the motor output current...

Page 33: ...the signal is output photo coupler ON Timing chart P O output timing for 1 1 STEP CWP CCWP P O 7 2 For a motor with the basic angle of 0 72 P O output time 1 1 STEP once in 10 pulses 1 2 STEP once in 20 pulses 1 4 STEP once in 40 pulses 1 10 STEP once in 100 pulses 1 20 STEP once in 200 pulses 1 40 STEP once in 400 pulses 5 6 7 8 1 2 3 4 1 0 9 0 1 2 33 ...

Page 34: ...s approx 70 or more O H A LED comes on At this time the motor output current is not blocked When this LED comes on stop operation and check if there is any abnormality occurring with the motor and the driver Provide mechanical cooling for example if this LED comes on while no abnormality is detected Continuous operation is possible unless this LED comes on WARNING 34 ...

Page 35: ...Instructions Manual 10 4 Dimensions R1 Unit mm 35 ...

Page 36: ... Fig 16 0 72 0 75 ON IH Fig 15 Fig 13 0 72 0 35 OFF IL Fig 14 TAMAGAWA SEIKI CO LTD 0 72 0 35 OFF IL Basic Angle Current A phase Setting DRIVE I SEL switch No Torque Data Fig No 0 72 0 75 ON IH Fig 12 0 72 0 75 ON IH Fig 11 0 72 0 75 ON IH Fig 10 0 72 0 75 ON IH Fig 9 0 72 0 35 OFF IL Fig 8 0 72 0 75 ON IH Fig 7 SANYO DENKI Co LTD 0 72 0 35 OFF IL Basic Angle Current A phase Setting DRIVE I SEL sw...

Page 37: ...Step angle Maximum value of the rotate speed is 100s 1 at 0 72 motor 2 The Maximum Starting Pulse Rate is represented as fs by the value at zero inertial load 3 Upon operation provide adequate allowance for torque 4 The stepping motor may attain high temperature depending on the operational conditions Use the stepping motor according to the Instructions Manual produced by motormakers Motor rotatio...

Page 38: ...Instructions Manual 39 ...

Page 39: ...Instructions Manual 38 ...

Page 40: ...Instructions Manual 40 ...

Page 41: ...Instructions Manual 41 ...

Page 42: ...dary sides 2 EMC directive This product declares the CE marking based on the EMC Directive by oneself Applicable Standards EN61000 6 4 EN61000 6 2 This product conducted EMC measurement with the system configuration for EMC EMC characteristic may vary depending on the configuration of the equipment that contains the driver or stepping motor Be sure to conduct EMC measurement with the product assem...

Page 43: ...Instructions Manual The main parts which revised by this manual R1 Addition of ADB 5F30A R2 Deletion of the directive number Parts Content P10 P29 P35 P42 43 ...

Page 44: ...and Service TEL 042 664 5384 FAX 042 666 2031 URL http www melec inc com Melec Inc Control equipment marketing department 516 10 Higashiasakawa cho Hachioji shi Tokyo 193 0834 Japan This Operating Manual is subject to change without prior notice for the purpose of product improvement C1610 ...

Reviews: