ADB-2F45U
Instructions Manual
〔Motor output Connector〕
〈Connection〉〈Crimping〉
〈Insertion〉〈Wiring〉
Housing Contact
Leads of the motor
J3
for J3
Orange(Black)
Blue(Green)
Red(Red)
Yellow(Blue)
White(Yellow)
Black(White)
●Color indications for leads of the motor indicate motor of the SANYO DENKI CO., LTD..
Color indications for leads of the motor in parentheses indicate motor of the
ORIENTAL MOTOR Co.,Ltd..
●Separate White(Yellow) line connected A.COM connector and
Black(White) line connected B.COM connector.
Do not short circuit White(Yellow) line and Black(White) line.
Doing so may cause breakage of the motor or the driver.
●Use a cable of 5m or less for the motor cable .
6-4.Inputting Power
Breakage of the machine or injury is
apprehended due to unexpected behavior of
the motor. Maintain the state where
emergency stop is enabled at any time.
(1) Input the DC power supply (DC+24V) in the cable that connected to No.1 and No. 2
terminals of J2.
Motor
1
1
3
2
2
4
B
ADB-2F45U
4
3
B
A
A
A.COM
5
5
B.COM
6
6
unipolar winding
(0.3mm
2
or more,
5m Max.)
-24-