meitav-tec TAT-SUPER Owner'S Manual Download Page 2

- 2  -

Index

1. Owner’s Manual………………………………………………………………………………………….………… 3-5

1.1 Turning the unit On or Off ………………………………………………………………………………..……. 3

1.2 Adjusting the set-point temperature ……………………………………………………………………..…… 3

1.3 Selecting system mode …………………………………………………………………………………..……. 3

1.4 Selecting fan speed…………………………………………………………………………………………….. 3

1.5 Enabling or disabling “fan on demand” option …………………………………………………………..….. 4

1.6 Timer ………………………………………………………………………………………………………..…… 3

2. Installation………………………………………………………………………………………………………….. 5

3. Wiring connections …………………………………………………………………………………………….… 5

4. DIP switch configuration……………………………………………………………………………………..….. 6

5. Temperature sensors connection and logic (T1 & T2)…………………………………………………..….. 6

6. Technician settings ………………………………………………………………………………...……...…….. 7-8

6.1 Enter technician settings ……………………………………………………………………………….…….. 7

6.2 Set point temperature limit for heat …………………………………………………………………..……… 7

6.3 Set point temperature limit for cool……………………………………………………………………………. 7

6.4 Lock buttons …………………………………………………………………………………………..………… 7

6.5 Offset for calibration of ambient temperature ……………………………………………………………..… 7

6.6 Enable or disable the LCD backlight…………………………………………………………..……..……….. 7

6.7 Temperature scale …………………………………………………………………………………..…………. 7

6.8 Enable or disable Auto speed selection ……………………………………………………………..………. 7

6.9 Enable or disable input IN,0 ……………………………………………………………………….…………. 7

6.10 Input IN1,0 configuration – change over sensor or remote switch ………………………………………. 7

6.11 Input IN1,0 polarity ………………………………………………………………………………………..….. 8

6.12 Cool only configuration ………………………………………………………………………………………. 8

6.13 Compressor delay (for AC configuration) ………………………………………………………………….. 8

6.14 System configuration - AC (HC) / Fan-Coil…………………………………………………………………. 8

6.15 Internal or External sensor ……………………………………….………………………………….……… 8

6.16 Economy set point for cooling ………………………………….……………………………………….…… 8

6.17 Economy set point for heating ………………………………………………………………………...…….. 8

6.18 Backlight On / Backlight Off………………………………………………………………………………….. 8

6.19 Restore defaults ………………………………………………...…………………………………………….. 8

Summary of Contents for TAT-SUPER

Page 1: ...Room thermostat TAT SUPER Owner s manual and Technician settings...

Page 2: ...3 Set point temperature limit for cool 7 6 4 Lock buttons 7 6 5 Offset for calibration of ambient temperature 7 6 6 Enable or disable the LCD backlight 7 6 7 Temperature scale 7 6 8 Enable or disable...

Page 3: ...n to switch between system modes 1 3 Selecting system mode Notes The or icons will flash with demand for cooling or heating The selection of Auto mode can be disabled by technician please refer to DIP...

Page 4: ...ding to the current status If the thermostat is ON the timer will switch it OFF If the thermostat is OFF the timer will switch it ON Press and hold the On Off button for 5 seconds the hours will appea...

Page 5: ...2 screws 6 Adapt the front frame panel into its place by pushing it towards the wall 5 3 Wiring connections Heat valve 0 5A Cool valve 0 5A RE HE One valve 0 5A RE HE RE HE For IN1 0 configuration ple...

Page 6: ...or Temperature Resistance Characteristics Temp C 7 2 10 0 12 8 15 6 18 3 21 1 23 9 26 7 29 4 32 2 Res K 115 8 100 9 88 1 77 1 67 7 59 6 52 5 46 4 41 2 36 6 Temp F 45 50 55 60 65 70 75 80 85 90 T1 Exte...

Page 7: ...Set point temperature limit for heat Range 10 30 C 50 86 F default 30 C 86 F 6 7 Temperature scale F blinking F C blinking C 6 6 Enable or disable the LCD backlight On The backlight is enabled Off Th...

Page 8: ...Cool and Heat configuration 3 Minutes compressor delay No delay AC HC Fan coil 6 Technician settings cont 8 6 11 Input IN1 0 polarity for remote off switch or remote economy switch PC Normally close...

Reviews: