2 Safety Instructions for Building-in Equipment
This building-in equipment has been designed and tested in accordance with the requirements of Standard
IEC60950-1 "Safety of Information Technology Equipment, including Electrical Business Equipment".
During installation of the building-in equipment in an end application (i.e. rack) additional requirements
in accordance with Standard IEC60950-1 have to be taken into account.
•
The building-in equipment is a class 1 - equipment and must be connected to an earthed outlet
(TN Power System).
•
The building-in equipment has been evaluated for use in office environment (pollution degree 2) and
may be only used in this environment. For use in rooms with a higher pollution degree more stringent
requirements are applicable.
•
The building-in equipment may not be opened.
•
Protection against fire must be assured in the end application.
•
The ventilation opening may not be covered.
•
The equipment/building-in equipment was evaluated for use in a maximum ambient temperature of 50
◦
C
(40
◦
C by using Rubidium).
•
For safe operation the building-in equipment must be protected by max 16 A fuse in the power installation
system.
•
Disconnection of the equipment from mains is done by pulling the mains plug.
2
Date: 5th April 2018
LANTIME M400