3 Important Safety Information

3 Important Safety Information

Please ensure that IMS modules designed for "hot-plugging" (modules that are removable and insertable while
a system is in operation) are always handled with the utmost care.

Before performing any maintenance work on the system:

We recommend making a backup of any stored configurations (e.g. using a USB flash drive or from the
Web UI)

Take note of the chapter "Prevention of ESD Damage".

Take note of the chapter "Power Supply".

3.1 Additional Safety Information

This manual contains important safety information regarding the installation and use of the device. Please read
it through fully before setting up the device for use.

This device may only be used for the purpose described in this manual. In particular, the specified operat-
ing limits of the device must be heeded. The person setting up the device is responsible for safety matters in
relation to any larger system in which the device is installed!

Failure to observe these instructions may have an adverse impact on device safety!

Please keep this manual in a safe and accessible place.

Target Readership

This manual is only intended to be used by qualified electricians, or by persons who have been appropriately
instructed by qualified electricians and who are familiar with applicable national standards and safety rules &
regulations, especially in relation to the installation of low-voltage (< 1000 V) installations.

IMS-RSC180

Date: December 17, 2021

3

Summary of Contents for IMS-RSC

Page 1: ...SETUP GUIDE IMS RSC180 Hot Plug Module December 17 2021 Meinberg Funkuhren GmbH Co KG...

Page 2: ......

Page 3: ...Start 11 5 1 Contents of Delivery 11 5 2 Disposal of Packaging Materials 11 6 System Installation 12 6 1 Important Information Regarding Hot Pluggable IMS Modules 12 6 2 Installation of Hot Pluggable...

Page 4: ...n GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Website https www meinbergglobal com Email info meinberg de Date December 17 2021 Manual Version 1...

Page 5: ...ctate how the module switches between clocks The status LEDs indicate which clock is currently selected as the Master Clock as well as the current operating state of the switch control module Please r...

Page 6: ...hrough fully before setting up the device for use This device may only be used for the purpose described in this manual In particular the specified operat ing limits of the device must be heeded The p...

Page 7: ...o an uncoated non conductive metal part of the system Use only tools and devices that are free of static electricity When transporting devices Devices must only be touched or held by the edges Never t...

Page 8: ...ent even after disconnec tion from the mains supply In the event that a power supply unit is no longer working e g defective please return it to Meinberg for repair Failure to observe these safety ins...

Page 9: ...motely over an Ethernet connection In remote mode the Master Clock can be selected using an SNMP command The most recent state set while in remote mode will be retained after control is handed back to...

Page 10: ...chover will be performed the current state will be retained and the outputs are disabled if so configured using the menu controls on the device s display Important To ensure that the automatic switcho...

Page 11: ...onds the set password will be reset for 30 seconds to a blank field i e you can simply press RETURN when prompted for the password After these 30 seconds the system will then restore the password to i...

Page 12: ...based on priority 10 EN_CLK Activates the clock with a sync event after reset only if DIP 1 is ON Figure DIP Switches on RSC180 Description of DIP_SW positions Switch 1 Positions 0 OFF If both clocks...

Page 13: ...Master is Clock 1 1 ON The Priority Master is Clock 2 If Switch 1 is ON Switch 10 Positions 0 OFF One clock is always enabled even if out of sync 1 ON A clock is only enabled after the first sync even...

Page 14: ...lease contact Meinberg immediately Only the recipient the person or company receiving the system may file claims or complaints against the forwarder for damage caused in transit Meinberg recommends th...

Page 15: ...acing it in order to keep your system on I O ESI and MRI Slots Hot Pluggable CLK1 CLK2 Hot Pluggable When a clock module is replaced or installed it is important to rescan Slots the reference clocks R...

Page 16: ...The module must be pulled carefully out of the guide rail Note that the module will be securely seated in the connector block inside the chassis a certain amount of force must be applied to release th...

Page 17: ...tputs PPO_1 PPO_4 Synthesizer Selection of output frequency 1 3 Hz to 10 MHz and phase 180 bis 180 Time Zone Selection of local time zone offset from UTC Enable Outputs Outputs always active or only w...

Page 18: ...here This enables the Master Clock to be selected via the Meinberg Device Manager software Please refer to the Meinberg Device Manager manual for a detailed overview and description of all con figurat...

Page 19: ...iguration and status monitoring Be a part of the ongoing improvement of the information contained in this manual Please contact our Technical Support team if you have any suggestions for improvements...

Page 20: ...olybrominated biphenyls PBBs polybrominated diphenyl ethers PBDEs bis 2 ethylhexyl phthalat DEHP benzyl butyl phthalate BBP dibutyl phthalate DBP or diisobutyl phthalate DIBP above the legal limits WE...

Reviews: