4 REL1000: Error Relay Module
4 REL1000: Error Relay Module
The REL1000 error relay output is connected to the TTL TIME_SYNC output of the reference clock (GPS,
GLONASS ...). If the internal reference clock has been synchronized by its source, the relay will switch to mode
"NO" (Normaly Open). In error case the relay switches to mode "NC" (Normaly Closed).
If the system isn’t equipped with a second clock and RSC switch unit, the relay can be switched by 10MHz or
PPS to monitor these signals.
Error Output:
Relay A:
Clock 1 / Notification Events
→
Relays
Relay B:
Clock 2 / PPS
Relay C:
Notification Events
→
Relay / 10MHz
In redundant mode, the jumpers on the REL1000 are set as follows:
Please note: The REL1000 can only be used for the IMS system M500 in the following jumper setting:
IMS-M500:
Relais A:
Clock 1
Relais B:
PPS
Relais C:
10MHz
IMS-REL1000 Setup Guide
Date: 21st November 2019
7