background image

Front view (Frontansicht) Converter

4. 

Fiber optic input, ST-connector

2. 

Fuse: 500 mA SB

ENGLISH

3. 

TTL outputs, BNC female

1. 

Power supply connector

3. 

TTL Ausgänge, BNC Buchse

4. 

Fiberoptischer Eingang, ST-Verbinder

2. 

Sicherung: 500 mA SB

1. 

Spannungsversorgung

DEUTSCH

3

4

2

1

Summary of Contents for CON/FO/TTL-4/DHS

Page 1: ...MANUAL Converter CON FO TTL 4 DHS November 19 2021 Meinberg Funkuhren GmbH Co KG...

Page 2: ......

Page 3: ...4 Fiber optic input ST connector 2 Fuse 500 mA SB ENGLISH 3 TTL outputs BNC female 1 Power supply connector 3 TTL Ausg nge BNC Buchse 4 Fiberoptischer Eingang ST Verbinder 2 Sicherung 500 mA SB 1 Spa...

Page 4: ...fety during Maintenance 10 2 7 Cleaning and Care 10 2 8 Prevention of ESD Damage 11 2 9 Return of Electrical and Electronic Equipment 12 3 System CON FO TTL 4 DHS 13 4 Attachment Technical Information...

Page 5: ...g Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Website https www meinbergglobal com Email info meinberg de Date November 18 2021 Conver...

Page 6: ...nderstood and fulfilled all requirements Hazard notices and other relevant information are classified and indicated as such in this manual according to the following system DANGER This signal word ind...

Page 7: ...rischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving parts IEC 60417 6172...

Page 8: ...e used for the purpose described in this manual In particular the specified operating limits of the device must be heeded The person setting up the device is responsible for safety matters in relation...

Page 9: ...1 additional measures such as installation of the device in an air conditioned electrical cabinet may be necessary Transport Unpacking Installation If the unit has been brought into the usage area fro...

Page 10: ...nd corners and that no objects are placed on the cables Ensure that all connections are secure make sure that the lock screws of the power supply plug are tightened when using a 3 pin MSTB or 5 pin MS...

Page 11: ...s socket on the appliance or the mains socket of the house installation is readily accessible for the user so that the mains cable can be pulled out of the socket in an emergency In accordance with IE...

Page 12: ...eristic T slow Nominal Current A 2 5 Ampere Switching Capacity H high max Voltage 250 V AC Power Supply DC Power Supply Have the spare fuse ready pay attention to the correct rated current characteris...

Page 13: ...ooled fire safe and shielded against electrical magnetic and electromagnetic fields Switching the Device Off in the Event of a Malfunction or when Repairs are Required It is not sufficient to simply s...

Page 14: ...ock fire hazard Unauthorized opening of the device or of individual parts of the device can also lead to considerable risks for the user and result in a loss of warranty as well as an exclusion of lia...

Page 15: ...n be attached to an uncoated non conductive metal part of the system Use only tools and devices that are free of static electricity When transporting devices Devices must only be touched or held by th...

Page 16: ...eft indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems When disposing of your old equipment please use the national return or collection sys...

Page 17: ...LWL card and a power supply mounted in a housing for DIN mounting rail ready for operation The serial interface and the input output signals of the system are accessible via connectors in the front p...

Page 18: ...V DC Power Consumption max 10 W Ambient Temperature 0 50 C Humidity 85 Protection Class IP20 4 2 Front Panel Connectors Name Type Signal Cable connection Power supply 3pin DFK male 20 60 V DC 3pin MS...

Page 19: ...7 A Output Parameter Max Power Pmax 8 0 W Max thermal energy BTU 27 30 BTU h Power 3 2 1 U 20 60 V max U 48 V N 4 4 Fuse The fuse protects against overload or short circuits and thus prevents damage t...

Page 20: ...sitivity 3 W min 25 dBm Connector ST conncector Cable GI50 125 m or GI62 5 125 m gradient fibre Fiber Optic In 4 6 TTL Output Output Signal TTL Level 2 5 Vpp into 50 Ohm Connection type BNC female Cab...

Page 21: ...olybrominated biphenyls PBBs polybrominated diphenyl ethers PBDEs bis 2 ethylhexyl phthalat DEHP benzyl butyl phthalate BBP dibutyl phthalate DBP or diisobutyl phthalate DIBP above the legal limits WE...

Page 22: ...diese Erkl rung bezieht mit den folgenden Normen und Richtlinien bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives EMV Rich...