MANUAL

ANZ14/ANZ14DCF/ANZ14NET

LED Display with

DCF77 or NTP Option

28th October 2019

Meinberg Funkuhren GmbH & Co. KG

Summary of Contents for ANZ14

Page 1: ...MANUAL ANZ14 ANZ14DCF ANZ14NET LED Display with DCF77 or NTP Option 28th October 2019 Meinberg Funkuhren GmbH Co KG...

Page 2: ......

Page 3: ...Mounting the Antenna 16 5 ANZ14 NET Option 17 5 1 Network Time Protocol NTP 17 5 2 Time and Date Display with NTP synchronized Reference 17 5 3 Error Code 18 5 4 Network Configuration 18 5 5 DHCP 19 5...

Page 4: ...9 Technical Specifications ANZ14 33 9 1 Rear Panel Connectors 34 9 1 1 Pin Assignment of the D SUB Connectors COM0 COM1 34 9 2 Rear Views 35 9 3 Time Strings 36 9 3 1 Format of the Meinberg Standard T...

Page 5: ...kuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2014 06 20 ANZ14 ANZ14DCF AN...

Page 6: ...ue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminently hazardou...

Page 7: ...ischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blades IEC 60417...

Page 8: ...for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the insta...

Page 9: ...on in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until the unit is...

Page 10: ...rly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure that...

Page 11: ...ket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside the assembly gr...

Page 12: ...there is a danger of overheating during operation Disturbances during operation can result Normal Operation The normal operation and the observance of the EMC limits electromagnetic compatibility are...

Page 13: ...risks for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not...

Page 14: ...e dangers to the user e g electric shock Liquid can destroy the electronics of the device Liquid penetrates into the housing of the device and can cause a short circuit of the electronics Only clean w...

Page 15: ...t when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity Transporting Assemblies As...

Page 16: ...duct symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specific...

Page 17: ...lfunction A power fail comparator resets the microprocessor if the supply voltage drops below a specified threshold A flash EPROM located in the microprocessor is used as program memory that can be lo...

Page 18: ...a time string once per second once per minute or only on request by sending an ASCII character ASCII code 3Fh 3 6 Power Supply The integrated mains power supply provides the clock with a stabilized vo...

Page 19: ...to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute will begin with the next time mark Our radio remote clocks decode the highly accu...

Page 20: ...ed at least 30 centimeters away from the clock unit and from solid steel A distance of several meters is recommended to all TVs or computer monitors In order to get the maximum signal the antenna shou...

Page 21: ...syncronization is feasible because of the several time references Every computer syncronizies itself by up to three valued time sources NTP enables the comparison of the hardware times and the adjust...

Page 22: ...0 internal error Er 01 no answer from NTP Er 02 NTP not synchronized Er 03 NTP stratum stratum of ANZ14 Er 04 05 for debugging only 5 4 Network Configuration To identify the ANZ14 in the network it is...

Page 23: ...ardware address of the Device Server which is found on the label beside the RJ45 connector in the rear panel In order for the ARP command to work on Windows the ARP table on the PC must have at least...

Page 24: ...you are presented the Welcome message and have to enter the access password If the password has been entered correctly you have to press enter again to start the setup tool Meinberg XPort Display MAC...

Page 25: ...cond part of your IP address and confirm it with RETURN Afterwards you can enter the third and finally the fourth part of the address After entering all four parts the screen looks like this IP Addres...

Page 26: ...e rwpublic An incoming SNMP request coming with this community string is granted read writeaccess meaning you can change a value At the moment there are no variables accessible for write access so thi...

Page 27: ...ver itself ANZ14 inquires the time information from the NTP server and sets its own freerunning clock The NTP request time is set to 64sec Display Delay Time This value causes the ANZ14 to display the...

Page 28: ...ed literature An OID looks like this 1 3 6 1 4 1 5597 20 2 2 All Meinberg units can be found under the 1 3 6 1 4 1 5597 branch the 5597 represents the unique world wide used enterprise ID of Meinberg...

Page 29: ...University of Delaware September 1989 Mills90 Mills D L Network Time Protocol Version 3 specification implementation and analysis Electrical Engineering Department Report 90 6 1 University of Delawar...

Page 30: ...e valid until the configuration is saved in the last sub menu of the setup menu 6 2 Brightness Br The brightness of the display can be set in steps from 0 to 9 where 0 represents the most dimmed brigh...

Page 31: ...sub menu The baud rate of the serial interface COM0 and COM can be set in this sub menu Button B is used to select one of the available baud rates button A is pressed to leave this and enter the next...

Page 32: ...llowing order CET Central European Time or CET EET East European Time or UTC without DST This setting is only relevant in the case of a DCF77 synchronized ANZ14 In case of a serial or NTP synchronized...

Page 33: ...IS 5 SAT 7 Computime The format of the strings is described in the chapter Time Strings 6 14 Serial Number SN The 16 digit serial number of the ANZ14 can be displayed in this menu The first 4 digits a...

Page 34: ...are rejected if YES is choosen with button B 6 17 Save Sv All changes made in the setup menu have to be saved before coming into effect so this sub menu has to be left with button A while YES is show...

Page 35: ...e ANZ14 time that is running free from this moment The ANZ14 keeps synchronisation to the master clock if the time string comes periodically once per second or once per minute This time string is spre...

Page 36: ...ootstrap loader of the microprocessor which is waiting for commands via the serial interface COM0 is activated Subsequently the new software can be transferred from any PC with a serial interface The...

Page 37: ...D and a status character in the serial output string Without RF signal the clock runs on XTAL with an accuracy of 10 6 after 24 hours of synchr operation indicated by LED Free run accuracy ANZ14NET 3...

Page 38: ...D RS232 RS422 shielded data line Antenna BNC 77 5 kHz shielded coaxial cable Power supply power cord receptacle 100 240 V AC cold device power plug or DFK connector 12 V or 24 V DC 2 wire 0 5mm2 min...

Page 39: ...M0 COM1 ANZ14 DCF with 240 VAC 50 60Hz Power Supply Antenna T1A 250V COM0 COM1 ANZ14 DCF with DC Power Connector Power 230V SB0 2A 250V ETH LTRX XPORT MAC Addr xxxxxxxxxxxx COM0 COM1 ANZ14 NET with Ne...

Page 40: ...ck status characters depending on clock type u GPS clock is running free without exact synchr PZF time frame not synchronized DCF77 clock has not synchronized after reset space 20h GPS clock is synchr...

Page 41: ...ile leap second v sign of the offset of local timezone related to UTC oo oo offset of local timezone related to UTC in hours and minutes ac clock status characters a clock has not synchronized after r...

Page 42: ...ng characters are possible N north of equator S south d equator lll llll longitude of receiver position in degrees leading signs are replaced by a space character 20h e longitude the following charact...

Page 43: ...tor of message ASCII 0 code 30h TSQ Telegram number ASCII 0 code 30h CC Command code ASCII S for SET code 53h CS Command code ASCII A for ALL code 41h ST Time status ASCII C for valid time code 43h yy...

Page 44: ...mm ssq CR LF The letters printed in italics are replaced by ASCII numbers whereas the other characters are part of the time string The groups of characters as defined below SOH Start of Header ASCII...

Page 45: ...2 yy year of the century 00 99 w the day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second xxxx time zone indicator UTC Univer...

Page 46: ...ters are part of the time string The groups of characters as defined below jj mm tt the current date jj year of the century 00 99 mm month 01 12 tt day of month 01 31 _ Space ASCII code 20h hh mm ss f...

Page 47: ...II numbers whereas the other characters are part of the time string The groups of characters as defined below T Start character sending with one bit accuracy at change of second yy mm dd the current d...

Page 48: ...ions of seconds 1 10 1 100 A Status A time data valid V time data not valid The following information regarding the receiver position is set to zero because receiver does not support this bbbb bb lati...

Page 49: ...das sich diese Erkl rung bezieht mit den folgenden Normen und Richtlinien bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives...

Reviews: