background image

How to mount the DAQ board

In most cases the DAQ board is already installed in the ME-Synapse (when bought as a package). If you want to 
mount an existing, supported ME CompactPCI board into the ME-Synapse, please note the following: Insert the 
board so it can easily slide in the two rails and is held securely. Plug the board into the internal backplane slot 
without using any force. The position of the CompactPCI IEL handle is at the bottom (ME-Synapse in upright posi-
tion) or on the right (flat on the side, see picture), so that it can snap into the grid when locked. Lock the board, 
again without using any force, and tighten all the screws at the front p anel and at the handle.

Note

 that the ME Compact PCI boards 

are not hotpluggable: The ME-Synapse 
has to be switched off (ie. unplug po-
wer supply and LAN) to pull/insert the 
boards.

Connectors, Status LEDs

 Power supply

Connect the supply power as shown in the picture above (

). If you don‘t use the power supply which is available 

as an accessory part from Meilhaus Electronic, please note the supply power input data as listed in the specifi-
cations. 

Note that the housing has to be connected to PE (Power Earth).

 PCI-Express x1 over cable interface

Connects the ME-Synapse-Express to your PC/Laptop. Use a 2 m PCI-Express x1 cable ME AK-PCIe-x1 (or com-
patible type) and an adaptor/host interface HE-ExpressCard (Laptop/ExpressCard) or HE-PCIe-x1 (desktop-PC/
PCI-Express x1).

 Status-LEDs

POW 

green  - 

Power OK (permanent)

RES 

red 

Downstream Reset (flashing when Reset)

RESP  - 

red 

PCI-Bus Reset (flashing when Reset)

 DAQ boards

Please find detailed information on the DAQ boards connectivity in the PDF user manuals supplied with the 
boards, see ME-Power-CD.

Connecting a Power-on

Connect the ME-Synapse Express and the host system (laptop or PC with the laptop or desktop adaptor in-
serted) only in power-off condition. Use a cable ME AK-PCIe-x1-2 (or compatible). Switch on the ME-Synapse first 
(by connecting the power supply), then start the host system

.

Software installation and initialisation (ME series boards)

Follow the ME-iDS software installtion guide of your ME board. Also note the relevant readme files.

Pair of rails

Grid for CompactPCI 
IEL handle

ME-SynapseExpress.indd   9

03.05.12   15:50