Manual ME-63Xtend Series
Rev. 1.2E
Meilhaus Electronic
Page 35
Pinouts
A2
Pinout ST2
Diagram 21: Pinout of the 25pin D-Sub connector ST2
Note for boards of ME-630, ME-4600 and ME-6000 series:
To
the 25pin D-Sub connector (ST2) of the ME-63Xtend series no
further signals are attached with exeption of VCC and ground
(see also diagram 19).
*„Daisy-Chain“ operation with the ME-1000:
If you connect a second board of the ME-63Xtend series to the
25pin D-Sub connector ST2 using the special connection cable
ME AK-D2578/1000 the digital I/Os P
x
16…31 of each port (A, B,
C, D) are attached (see also chapter 2.6 "Connection Options" on
page 30).
Condition is using the special connection cable ME AK-D78/1000
to connect boards of the ME-63Xtend series to the ME-1000/64
(up to 64 channels) resp. ME-1000/128 (up to 128 channels).
Note
: ME-1000/64 + ME-1001 = ME-1000/128.
onl
y ME-1400A/B
PC0
PC2
PC4
PC6
(Clk 0)
(Out 0)
(Gate 1)
(Clk 2)
(Out 2)
VCC
VCC
PC-GND
PC-GND
PC1
PC3
PC5
PC7
(Gate 0)
(Clk 1)
(Out 1)
(Gate 2)
(OSC/IR IN)
VCC
PC-GND
PC-GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
*P
x
16
*P
x
18
*P
x
20
*P
x
22
*P
x
24
*P
x
26
*P
x
28
*P
x
30
n.c.
VCC
VCC
PC-GND
PC-GND
*P
x
17
*P
x
19
*P
x
21
*P
x
23
*P
x
25
*P
x
27
*P
x
29
*P
x
31
n.c.
VCC
PC-GND
PC-GND
ME-1400(A/B)
ME-1000/1001