9617722
32 / 48
6.11
Replace dosing agent
Risk of injury from dosing agent!
Wear safety glasses.
Wear rubber gloves.
Warning
Caution when handling dosing agents!
They are sometimes irritants substances.
Observe the manufacturer of the dosing agent's applicable
safety regulations and safety data sheets.
Follow the manufacturer of the dosing agent's first aid
measures in an emergency.
Caution
*) MEIKO recommends hanging up a description of the first aid measures near the ma-
chine
Malfunctions due to incorrect rinse agent/water softener!
Only use rinse agent / water softening agents in our
cleaning and disinfection machines for which MEIKO have
given their written approval.
Make sure that medium dosing containers are always up-
right.
Only use medium dosing containers in which the suction
lance is vertical.
Caution
Malfunctions and damage due to include cleaning!
When changing product, clean the entire dosing agent
with water.
Caution
Replace dosing agent as follows:
Open door to container for dosing agent (see 4.3 Structure) with key.
Remove suction tube from the dosing agent container.
Insert new dosing agent container, make sure that medium dosing containers are al-
ways upright
Connection suction tube to dosing agent container, suction tubes must be vertical in
the medium dosing containers!
Close door to container for dosing agent (see 4.3 Structure) with key.