3.13 Tabling Attachment
The DV 200.2 can be positioned in
either of two tabling configurations;
straight through, or in a corner
installation. See Figure 3-15.
1.
IF
the machine will be
positioned in a corner, perform
the following steps before
attaching the tables:
•
Position the machine so that
the LEFT REAR corner of
the machine faces the
corner of the wall, as shown
in Figure 3-15. For corner
installations, this placement
is necessary to ensure that
the control panel can be
reached by the operator.
•
Remove the FRONT LEFT
rack guide as shown in
Figure 3-15. The guide is
held in place by two screws.
Replace the guide on the
LEFT SIDE position in the
2 mounting holes provided.
2. Position the machine and tables
as follows:
•
Check that the centerline of
the opening at the end of
each table is aligned with
the centerline of the rack
track of the machine. See
Figure 3-16.
•
Check that the surface
height of each table
matches the height of the
rack track of the machine,
to ensure a smooth transi-
tion. The standard table sur-
face height is 34” (864mm).
•
Check that the machine is
level.
The height of the machine, and
of most tables, can be adjusted
by rotating the feet at the end
of the legs.
Figure 3-15: Straight-through and
corner tabling configurations
Straight-through
Control
panel
For a corner
installation ONLY,
move the rack rail
guide from the
FRONT LEFT
position to the LEFT
SIDE position.
Corner installation:
Left rear corner of machine
MUST face corner of wall to
ensure access to control panel.
Before
After
Figure 3-16: Aligning the table centerlines
with the dishmachine
Centerline of
rack track
Centerline of
table opening
Centerline of
rack track
Centerline of
table opening
Straight-through installation
Corner installation
S
ECTION
3 - I
NSTALLATION