The total magnification can be calculated by multiplying the magnification of the eyepiece 

with the magnification of the objective. The magnifications are displayed in the table below:

Eyepiece

Objective

Magnification

10x

4x

40x

10x

10x

100x

10x

40x 

400x

10x

60x

600x

10x

100x

1000x

Object stage

On the basic models the slide is placed beneath the object clips. On the other models into 

the clamp of the mechanical stage (G) and can be carefully moved into X- and Y- directions. 

Focusing the specimen is done by using the coaxial coarse- and fine adjustment knobs (I). 

Coarse- and fine adjustment

The coarse- and fine adjustment knobs (I) for the height adjustment of the object stage are 

mounted together on one (1) axle (co-axial). On both fine adjustment knobs there is a gradu-

ation with intervals of 0.002 mm.  This can be used to measure depths in a specimen.

Abbe condenser with iris diaphragm

Beneath the object stage an Abbe condenser (M) N.A. 12.5 is mounted. The condenser can 

be adjusted in height by means of turning.  With this one can focus the light on the specimen 

by which the contrast can be optimised. The condenser is factory pre-centered.

The iris diaphragm with filter holder is mounted beneath the condenser. The light intensity 

can be adjusted by changing the flexible opening. 

Illumination MT-30/MT-90 series serie

The LED illumination of the MT-30/MT-90 series is equipped with rechargeable batteries. 

The length of use after charging is about 60 hours. The full charging time is about 10 hours. 

At First use the batteries have to be fully charged. Connect the cable to the mains socket. 

The illumination has the following specifications:

• 

LED   

: 1W, 300 mA.

• 

Charger 

: Primary AC 85 - 265 Volt-50Hz.

• 

Batteries 

: 3 NiMh, AA type, 1.2 Volt  1600 - 2000 mA.

Summary of Contents for MT-30 Series

Page 1: ...MT 30 MT 90 Series Advanced Academic Microscopes Advanced Academic Polarizing Microscope INSTRUCTION MANUAL...

Page 2: ...developed for use at schools and laboratories The maintenance requirement is limited when using the microscope in a decent manner This manual describes the construction of the microscope how to use th...

Page 3: ...picture on the next page A Tube mono bino trino 360 rotatable B Dioptric adjustment bino type C Stand arm D Revolving nosepiece for 4 objectives E Objectives F Safety device G Object stage mechanical...

Page 4: ...MT 30 MT 90 Series Advanced Academic Microscopes Advanced Academic Polarizing Microscope INSTRUCTION MANUAL A B C D E F G H I K O N M L...

Page 5: ...0 MT 90 series range The MT 30 MT 90 series range microscopes are standard equipped with 1 or 2 widefield eye pieces WF10x O and semi plan objectives as mentioned below in table 1 Optical specificitio...

Page 6: ...axial On both fine adjustment knobs there is a gradu ation with intervals of 0 002 mm This can be used to measure depths in a specimen Abbe condenser with iris diaphragm Beneath the object stage an Ab...

Page 7: ...ANUAL Preparing the Microscope for Use Remove the packing and put the microscope on a flat table The objectives are pre mounted Put the plug into the mains supply and switch on the microscope Sit comf...

Page 8: ...h other until a compound field of view is achieved see drawing above Close the left side eye and focus looking through the right side eye with the coarse and fine adjustment knobs I Now close the righ...

Page 9: ...40x objective Turn the revolving nosepiece so the S100x objective almost reaches the click stop Put a small drop of immersion oil on the centre of the slide Now turn the S100x objective so that you fe...

Page 10: ...ch lower Caution Never put a drop of xylol or alcohol directly on the lens of the objective It could enter the objective and dissolve the glue that holds the lenses Avoid oil contact with any of the o...

Page 11: ...lowest lens of the eyepiece By using the Allen key the eyepiece can be removed from the tube Clean the outside of the lens In case there is still dust visible please check if the dust is in the eyepie...

Page 12: ...aring can be lubricated Changing the batteries of the MT 30 MT 90 series Caution Always remove the power cable from the main supply Remove the smal lid out of the bottom cover of the microscope Place...

Reviews: