Forks with flow divider – flow
meter with Autostop
The flow meter needs to be
connected to the return flow of the
left fork. Remove the plugs from
the flow meter. Connect one port
of the flow meter to the ‘R’ port on
the flow divider.
Connect the other port of the flow
meter to port ‘1’ of the 3/2 valve for
the Autostop function. Connect
port ‘3’ of the 3/2 valve with a T-
coupling to the ‘P’ port on the flow
divider. Finally connect port ‘2’ of
the 3/2 valve to the return hose of
the lift truck.
Check all connections for leakage
before operation. Fully extend and
retract the forks five times to
remove any air from the hydraulic
system.
16
T
P
Lift truck
Flow meter
Left fork
Right fork
P
R
P
R
P
B
A
Flow divider
R
2
3
1
3/2 valve
R
R