Hydraulic installation on KOOI-REACHFORKS®
The flow meter has no dedicated pressure or return ports.
All flow meters and valves are delivered with plugs in the hydraulic ports. Remove these
before starting assembly.
All hydraulic equipment need to be installed by an authorized technician.
Forks with flow divider – flow
meter without Autostop
The flow meter needs to be
connected to the return flow of the
flow divider. Remove the plugs from
the flow meter. Connect one port of
the flow meter to the ‘R’ port on the
flow divider.
Connect the other port of the flow
meter to the return hose of the lift
truck.
Check all connections for leakage
before operation. Fully extend and
retract the forks five times to remove
any air from the hydraulic system.
15
T
P
Lift truck
Flow meter
Left fork
Right fork
P
R
P
R
P
B
A
Flow divider
R
R
R